Assume steady fully developed laminar flow of a Newtonian fluid in a long circular tube, with no slip at a rigid wall. The Hagen-Poiseuille equation gives the volume flow rate
where is the lumen radius, the tube length, the dynamic viscosity and the pressure drop. If , and remain fixed, then
Thus doubling the flow requires
This estimate neglects pulsation, arterial compliance, entrance losses, the detailed shape of a stenosis and changes in the rest of the circulatory resistance. It treats blood as a homogeneous Newtonian fluid and assumes that enlarging the artery does not change its applied pressure drop. These assumptions supply the intended fourth-power scaling; an actual circulation need not keep that pressure drop fixed.
At terminal speed, the downward excess weight is balanced by Stokes's law drag:
The subtraction of the displaced water mass includes buoyancy. Hence the Stokes settling velocity is
A density is needed but is not supplied. For the estimate, take a dense iron oxide represented by magnetite, with , and water with . This gives
Using the diameter for the particle Reynolds number gives , which supports the creeping-flow assumption. The model assumes a dilute isolated sphere far from walls and no imposed flow. The precise numerical speed depends on the unspecified oxide phase and particle density; the estimate is of order .
The polymer overlap concentration is reached when there is roughly one chain per coil volume. If is the chain molar mass, choose the explicit geometric convention , where is the radius of gyration. Then
Here is mass per solution volume and is the Avogadro constant. A good solvent gives with , approximated by in the Flory approximation. With a polystyrene repeat-unit molar mass of about , the chain has approximately repeat units. This fixes the chain length but not the size amplitude: the problem supplies no statistical segment length or measured coil size.
For a numerical estimate, use the good-solvent size calibration for polystyrene,
This empirical calibration is quoted for benzene or toluene near room temperature at molar masses above ; using it here is a modest extrapolation to . It gives . Thus
The unrounded calibration gives about . This is an estimate under a stated extra material input, not a unique number determined solely by molecular weight and the phrase good solvent. Choosing a different coil-volume convention changes its prefactor. The robust chain-length dependence is for a flexible good-solvent coil.

Articles by others on the same topic (0)

There are currently no matching articles.