An organic substance may also contain nitrogen, sulfur, phosphorus, halogens and, in some cases, metals or other elements. “Organic” does not mean “made of only carbon, hydrogen and oxygen”. Detection generally requires converting a covalently bound element into a species that an appropriate inorganic test can recognize.
A historically available general method is the sodium fusion test. Fusion converts suitable nitrogen-containing material into cyanide, sulfur into sulfide, and chlorine-, bromine- or iodine-containing material into the corresponding soluble halides. The cooled reaction material is worked up to an aqueous extract, with separate portions reserved for separate tests. The transformations are analytical conversion principles, not claims that every nitrogen or sulfur compound must give quantitative recovery under any fusion conditions. Blanks and a known positive material are essential when a negative result is to be interpreted.[ref]
For nitrogen, a suitable cyanide-containing extract is treated with a fresh iron(II) reagent and then brought through the appropriate oxidation and acidification sequence to obtain Prussian blue. Formation of ferrocyanide is represented byThe eventual ferric ferrocyanide material provides the blue observation. It is not sufficient simply to add any iron salt and assume that a positive blue must appear. Another classical principle converts nitrogen in suitable organic materials into Ammonia by heating with alkaline reagents, then recognizes the ammonia in a receiver. That test has substrate-dependent limitations and is not a universal replacement for complete nitrogen analysis. A later specialized nitrogen-digestion protocol must not be silently attributed to 1865.
For sulfur, a sulfide-containing alkaline extract can give black lead sulfide with a suitably introduced lead reagent:The strongly acidic form of the reagent conditions changes the available sulfide, so conditions must be controlled. Oxidizing the material to sulfate and identifying a persistent barium sulfate precipitate supplies another principle, using sulfur-free reagents and excluding pre-existing sulfate contamination. If nitrogen and sulfur occur together, thiocyanate formation can alter a fusion test; failure of the expected cyanide reaction is not conclusive evidence that nitrogen is absent.
For chlorine, bromine and iodine, remove interfering cyanide and sulfide by an appropriate controlled treatment of a separate extract portion, then use silver nitrate under suitable nitric-acid conditions. The precipitates are ordinarily white silver chloride, cream silver bromide and yellow silver iodide. Their differing behaviour with aqueous Ammonia provides corroboration: chloride dissolves relatively readily, bromide requires stronger conditions, and iodide is resistant. Do not use hydrochloric acid to prepare the portion in which original chloride is being sought. Fluorine requires a different recognition method: soluble silver fluoride means this precipitation scheme does not provide an equivalent fluoride test.
For phosphorus, oxidize a suitable portion to phosphate, then apply a phosphate test such as yellow ammonium phosphomolybdate formation under the proper acidic conditions. Arsenic species and other interferences must be excluded when relevant. Mineral ash can reveal metal constituents through their specific precipitation or flame reactions, but oxidation during ashing can change their original chemical form. Absence of a visible ash does not prove absence of every metallic or otherwise volatile element.
A positive result identifies an element or an operationally generated ion; it does not establish which functional group contained it in the original molecule. Conversely, an incomplete conversion can give a false negative. This is why the three-element premise used in the preceding combustion calculation should be checked rather than accepted merely because a substance is described as organic.
Iron in nonoxidizing hydrochloric acid principally gives an iron(II) solution; tin in oxidizing aqua regia principally gives a tin(IV) solution. These are the two preparations paired most directly by “respectively”. Their contrast is clearer when the other acid treatment of each metal is considered as well. “Nitrohydrochloric acid” is the historical name for aqua regia, containing nitric and hydrochloric acids.
For iron in dilute hydrochloric acid,The fresh solution is typically pale green when sufficiently concentrated. Hydroxide gives a pale green precipitate of iron(II) hydroxide, which darkens and turns brown on exposure to air as oxidation proceeds. Ammonia can similarly precipitate a ferrous hydroxide rather than forming a stable soluble excess-ammonia complex under the usual test conditions. Ferricyanide gives a deep blue product; the modern structural account of this blue material should not be replaced by an overly literal formula inferred solely from the reagent names. Ferrous solution also reduces a suitable oxidant such as acidic permanganate:
If instead oxidizing acid treatment produces iron(III), the solution exhibits ferric reactions: hydroxide or Ammonia gives red-brown iron(III) hydroxide; thiocyanate gives a strong red colour; and ferrocyanide gives Prussian blue. Chloride complex formation affects colour and some equilibria, so “yellow” is not a universal iron(III) identity test. Oxidizing aqua regia supplies this ferric comparison rather than merely generating more of the same ferrous salt.
Tin in ordinary hydrochloric acid gives a tin(II) solution with hydrogen evolution:Its characteristic property is reducing power. With mercury(II) chloride, controlled addition can first form white mercury(I) chloride and then, with further reductant, grey metallic Mercury:The chloride formulae are useful net bookkeeping, not a complete statement of all aqueous chloro-complexes.
In aqua regia, tin is oxidized predominantly to tin(IV). A representative balance, choosing nitrogen monoxide as the nitrate-reduction product, isActual gas products depend on the acid conditions. Sufficient chloride and acidity retain tin in solution; dilution can cause hydrolysis and precipitation of hydrated tin(IV) oxide. This differs from the simple expectation that every dilution leaves unchanged molecular in water. Hydrogen sulfide in suitable acidic conditions gives yellow tin(IV) sulfide, compared with brown tin(II) sulfide from a stannous solution. Tin(IV) does not reproduce the characteristic reducing reaction of fresh tin(II) with mercuric chloride; reduction to tin(II) is needed first. Oxidation during storage can therefore change the reactions of a nominally stannous preparation.
Confirm hydrogen cyanide by chemical tests on a suitable separated fraction, then estimate its amount with a defined quantitative assay. Here “hydrocyanic acid” means in water, also historically called prussic acid. Smelling or tasting is not an analytical test: hydrogen cyanide is acutely poisonous, and its characteristic odour is not reliably perceived.[ref]
Hydrogen cyanide emergency response information by NIOSH. Agent characteristics; odor warning and exposure hazards
A coloured or complex liquid can mask the tests or contain interfering ions. Historically, controlled distillation separated volatile hydrogen cyanide from many nonvolatile constituents; a receiving solution captures the analyte. In a modern analytical apparatus, the closed transfer system includes a condenser and an alkaline gas absorber. The receiver converts volatile hydrogen cyanide into less volatile cyanide:The measured fraction must be defined: free hydrogen cyanide in the original liquid is not automatically identical to “total cyanide” released from complexes by a more aggressive preparation. A blank, a known positive control and recovery checks help distinguish a negative sample from failed separation or reagent failure.[ref]
Cyanide in Waters and Extracts, Method 9014 by United States Environmental Protection Agency. §§1–4, scope and interferences; §§8–9, sample handling and quality control
For the historical iron test, make a separate test portion alkaline, introduce fresh iron(II) salt together with an iron(III) source, and finally acidify as specified by the historical procedure. Cyanide first forms ferrocyanide with iron(II); iron(III) then gives the characteristic Prussian blue precipitate. Idealized balances explaining the recognition chemistry areReal Prussian blue can be hydrated and nonstoichiometric; the second chemical equation is a useful idealization. The acid stage also removes obscuring iron hydroxide precipitates. These steps explain the old mixed iron-salt test, rather than assuming that cyanide simply reacts directly with any iron salt to give blue material.[ref]
British Pharmacopoeia (1867). Acidum Hydrocyanicum Dilutum, printed p. 14, mixed ferrous/ferric salt, potash and acid sequence
A second aliquot can be examined with silver nitrate. Silver cyanide is white, but whiteness alone is not specific because silver chloride and other precipitates can interfere:For a purified aliquot, precipitate the cyanide quantitatively with silver nitrate, separate the silver cyanide, wash it free of soluble salts, dry it to constant mass and weigh it. The precipitation conditions must avoid losses as volatile hydrogen cyanide and dissolution as dicyanoargentate; interfering precipitates must be excluded. For complete collection of pure, dry silver cyanide, gravimetric analysis givesThus mass units of silver cyanide correspond to about mass units of hydrogen cyanide. The 1867 pharmacopoeial check was grains of dry silver cyanide from grains of the diluted acid, corresponding approximately to its stated strength by mass.[ref]
British Pharmacopoeia (1867). Acidum Hydrocyanicum Dilutum, printed pp. 13–14, identity, strength and silver-precipitation assay
A fraction or dilution of a sample requires the corresponding scaling back to the original quantity.Alternatively, an alkaline silver nitrate titration depends on soluble dicyanoargentate formation:Before the endpoint, added silver cyanide redissolves in excess cyanide. In the classical version, the first persistent turbidity marks the end of this clear-solution stage. For a clean sample, a standardized silver nitrate molar concentration , a blank-corrected endpoint volume , and an aliquot fraction of the total recovered sample,Here is in litres if is in . Divide by the original sample mass for a mass fraction, or by its original volume for a mass concentration. No numerical sample amount is supplied, so no particular measured concentration can be inferred.
Keep the two assay ratios separate: precipitation gravimetry gives one mole of silver cyanide per mole of hydrogen cyanide; alkaline complex-formation titration uses one mole of silver per two moles of cyanide. A modern version of the latter uses a rhodanine indicator and a blank, as in EPA Method 9014; that indicator procedure is a modern comparison, not a detail assigned to 1867.[ref]
Cyanide in Waters and Extracts, Method 9014 by United States Environmental Protection Agency. §11.3, silver-to-cyanide reaction, rhodanine endpoint and blank; §12.2, calculation