Wilson cloud-chamber experiment 2026-10-18
Charles Thomson Rees Wilson's 1927 lecture recalls Electron cloud trails produced with X-rays in 1911, then alpha particle trails from a radium-tipped source. The improved 1912 chamber had a wide, shallow space with a suddenly falling floor to limit stirring. A roof–floor clearing electric field removed unwanted ions. Sharp photography required expansion, then the ionizing particle, then illumination.[ref]
On the Cloud Method of Making Visible Ions and the Tracks of Ionizing Particles by Charles Thomson Rees Wilson. Nobel Lectures, Physics 1922–1941; Wilson, 1927 Nobel lecture, pp.199–201, Fig.3: apparatus and operating sequence
The piston mechanism connects the space beneath the moving floor to an evacuated vessel: opening the valve lets the floor drop. Water in a trough supplies the vapor. The Smithsonian's surviving demonstration object is explicitly a 1961 replica of the 1912 apparatus.[ref]
Wilson’s Cloud Chamber, Replica of Cavendish Lab Apparatus by Smithsonian Institution. Smithsonian Institution, Wilson's cloud chamber, replica of Cavendish Lab apparatus, object nmah_700205, “History and basic principle” and “Date made”
After dust removal, X-rays increased droplet formation above a lower expansion threshold; larger expansions also produced dense background cloud.[ref]
On the Cloud Method of Making Visible Ions and the Tracks of Ionizing Particles by Charles Thomson Rees Wilson. Nobel Lectures, Physics 1922–1941; Wilson, 1927 Nobel lecture, pp.194–197: cloud limits and clearing controls