For a linear viscoelastic fluid, causal superposition gives
The relaxation modulus is the stress response to a unit small step of shear strain. The equation assumes an isotropic reference state and deformations and rotations small enough over the significant memory times that nonlinear transport and strain products can be neglected. Small-amplitude motion can have high frequency; linearity does not require low frequency by itself. The infinite-past integral encodes the preceding history, rather than assuming that stress vanishes whenever the present rate vanishes.
For a small constant shear rate maintained from the remote past, the rate can be taken outside the integral. Therefore the zero-shear viscosity is
provided the kernel is integrable, with any instantaneous contribution counted fully. A nondecaying solid-like modulus would not yield a finite fluid viscosity.
To linearize the stated Oldroyd-B model, put and absorb the isotropic into pressure. The products of the small deformation tensor C and velocity gradient are second order. Using the paper's derivative-index-first gradient convention therefore gives
An integrating factor, with the prescribed preceding history, gives . Thus the linear nonpressure stress is
The regular relaxation tail is , while the solvent is instantaneous. Equivalently, the instantaneous solvent term in a relaxation modulus can be represented by
Here the causal endpoint delta is defined by . If instead a symmetric Dirac delta is assigned half its mass at the endpoint, the same solvent term is written . Stating the convention prevents a factor-of-two error in the viscosity; the explicit stress formula above has no such ambiguity.
In a cone-and-plate rheometer, the small-angle gap is and the local wall speed is , so the shear rate is independent of radius to leading order: . Write for shear stress and for its polymer part. The linear constitutive response is
The uniform shear stress gives torque
For the initial steady torque T, put and , . The steady polymer stress is , with . Hence the initial angular velocity is
For , the total stress is , but the polymer stress is continuous at the torque reversal. Since , a finite jump in shear rate is possible even though P cannot jump. Its immediate value is
Eliminating P from the constant-stress equations for gives
The decay time is the Retardation time of an Oldroyd fluid . Solving this first-order equation with the actual initial value yields the complete torque reversal of a linear Oldroyd fluid:
In particular, but is more negative. The stored polymer stress initially retains its old positive sign, requiring a larger negative solvent shear stress to attain the new negative total torque. This produces the backward-speed overshoot and its subsequent relaxation. Apparatus inertia would smooth the instantaneous jump, but is neglected in the question. The torque must be sufficiently small for the entire transient, including its enhanced initial rate, to remain in the linear viscoelastic regime; small pre-reversal rate alone is not sufficient when is large.
Use a rheometer, for example a cone-and-plate rheometer or a parallel-plate rheometer, to impose a small deformation and measure the required torque, or impose a torque and measure the deformation. The apparatus geometry converts these into shear stress and strain. First check that reducing the imposed amplitude does not change the normalized response; this identifies the linear regime and avoids yielding or structural rearrangement.
Three complementary protocols characterize the material's memory. In a stress relaxation experiment impose a small step and hold the deformation fixed. The output is the relaxation modulus , revealing how stored stress decays and whether an elastic plateau remains. In a creep compliance measurement impose a small stress step and record . Removing the load also distinguishes recoverable deformation from permanent flow.
In small-amplitude oscillatory shear, impose sinusoidal strain over a range of frequencies and measure both stress amplitude and phase. With , fit
The outputs are the storage modulus and loss modulus , or equivalently amplitude ratio and loss tangent . These measure elastic storage and dissipative response, respectively. The step experiments give time-domain information and the oscillatory experiment gives the corresponding frequency-domain response. All comparisons must use the same deformation convention and controlled temperature.
Rheometer Created 2026-09-24 Updated 2026-11-05
A rheometer imposes a controlled stress or deformation and measures the complementary response. In a rotational instrument, a sample fills a gap between surfaces such as concentric cylinders, parallel disks or a cone and plate. The directly controlled or measured quantities include torque, angular displacement and angular velocity; the geometry converts these into shear stress, shear strain and shear rate.[ref]
For example, a small-angle cone-and-plate rheometer produces approximately uniform shear rate and shear stress , with cone angle , radius , rotation rate and measured torque . A parallel-plate rheometer instead has a radius-dependent shear rate. The conversion therefore requires the appropriate flow model. Wall slip, edge failure, temperature drift and the instrument's own inertia can mimic a material response, especially for very weak or rapidly varying signals.
Torque reversal of a linear Oldroyd fluid Created 2026-10-14 Updated 2026-11-05
In an inertialess cone-and-plate rheometer, reverse a steady torque from T to -T at time zero. The polymer shear stress remains continuous while the positive solvent viscosity allows the rate to jump. The linear stress equation gives and the displayed velocity for t>0, where . The transient backward speed exceeds the final backward speed because stored polymer stress initially retains its former sign.