David Brynn Hibbert 2026-11-05
David Brynn Hibbert, also known as Brynn Hibbert, is an analytical chemistry researcher whose work combines chemometrics, electrochemical measurements and metrological traceability. His university profile records his tenure in the UNSW analytical-chemistry chair from1987 to2013 and his editorship of the IUPAC terminology compendium known as the Orange Book. The Royal Society of New South Wales explicitly verifies his full name.[ref]
With Paul De Bièvre, René Dybkær and Aleš Fajgelj, David Brynn Hibbert coauthored the IUPAC report on the concepts and implementation of metrological traceability in chemical measurement. Its goal was a consistent account of how a result is related to a reference, including the concepts needed to communicate that relationship.[ref]
An original illustration explains the value of a measurement model in chemometrics. Suppose two ideal sensors give and , where is the target concentration and an interfering response. Their mean recovers , while their difference diagnoses . If both instead respond as , averaging cannot remove the interference. The chemical response model determines what additional measurements identify; having more numbers alone does not guarantee more independent information.
Figure 1.
David Brynn Hibbert, portrait identified by his UNSW profile
.
Paul De Bièvre 2026-11-05
Paul De Bièvre was a researcher in isotope ratio measurements, reference materials and chemical metrology. His IUPAC Council biography records leadership in isotope mass spectrometry and isotope reference materials at the European Commission's nuclear-measurement laboratory, later the Institute for Reference Materials and Measurements.[ref]
With René Dybkær, Aleš Fajgelj and David Brynn Hibbert, Paul De Bièvre prepared the2011 IUPAC report on metrological traceability of chemical measurement results. The report's stated aim is a consistent view of traceability's creation, meaning and role in chemical measurement.[ref]
An original isotope-counting example shows why a ratio must be specified. If a hypothetical two-isotope material contains80 units of isotope A and20 of isotope B, its ratio A/B is4, while the fraction A/(A+B) is0.8. Multiplying a sample's total amount by ten changes neither value. An instrument response ratio still requires a measurement model relating its signals to those isotope amounts; unequal response to the two isotopes can alter the observed ratio.
This connects isotope measurements with reference material characterization and measurement calibration. A precise signal ratio is useful only when its relation to the specified measurand and reference is established, with appropriate measurement uncertainty. Paul De Bièvre's documented work joined those experimental and conceptual aspects.
René Dybkær 2026-11-05
René Dybkær worked on measurement concepts and terminology in laboratory medicine. The IUPAC traceability report identifies him with the Department of Standardization in Laboratory Medicine at Frederiksberg Hospital, Denmark, and names him as a coauthor with Paul De Bièvre, Aleš Fajgelj and David Brynn Hibbert.[ref]
The report develops a shared account of metrological traceability for chemical measurement. Such terminology matters because a result must identify the measurand and reference relationship before numerical comparisons become meaningful. A chemical name, number and unit together specify more than an instrument indication alone.
For an original conversion example, a stipulated compound with molar mass at has mass concentration . The numbers2 and200 describe equivalent content under that specification, rather than disagreement between laboratories. Conversely, equal numbers attached to different quantity definitions need not be equivalent. Uncertainty in the inputs also belongs in the conversion's measurement uncertainty.
René Dybkær's coauthored standards work addresses this need to make the meaning of a measurement communicable. The example is an original illustration of the problem, not data attributed to his experiments or a statement of a clinical decision threshold.