Early-time resistance dominance of a filling response means that the initial volume admitted by a pressure step is governed mainly by airway resistance, even when the eventual volume depends strongly on lung compliance. For a passive compartment with constant airway resistance , lung compliance , imposed pressure increment and initial added volume zero,Initially the elastic recoil increment is zero, so the initial volumetric flow rate is . The initial slope identifies within this model, not .
A Taylor series makes the separation explicit:Information about lung compliance first enters the curvature. Recovering that curvature from noisy early measurements can be much harder than measuring the initial slope. The dimensionless ratio controls the approximation: the exact response divided by the resistance-only prediction is .
For an original calculation, take , and compare with . Both predict initial volumetric flow rate 1 L/s. At 0.05 s their admitted volumes are approximately 0.04877 and 0.04975 L, although their equilibrium added volumes are 1 and 5 L. An apparently precise short filling trace can therefore provide little discrimination between very different equilibrium lung compliances.
This is an ideal pressure-step calculation. A finite instrument response, an unknown driving pressure, nonlinear airway resistance or multiple compartments changes what can be inferred. A primary ventilation study explicitly measured multiple expiratory time constants because deflation need not follow one exponential.[ref]
Static and Dynamic Measurements of Compliance and Driving Pressure: A Pilot Study by Pierre Tawfik and others. Materials and Methods, Study Procedures: two expiratory time constants rather than an assumption of uniexponential deflation
An early filling slope and an equilibrium lung compliance answer different experimental questions. Articles by others on the same topic