ELODIE spectrograph 2026-10-18
Built by André Baranne, Michel Mayor, Didier Queloz and colleagues, the ELODIE fiber-fed spectrograph carried light from Haute-Provence's 1.93-metre telescope through optical fibers. Its echelle grating dispersed light in high diffraction orders; an optical prism and grism cross-disperser separated them perpendicularly on a charge-coupled device. This cross-dispersed echelle spectrograph achieved spectral resolving power . A simultaneous thorium reference tracked instrumental drift. Wavelength calibration mapped detector positions to wavelengths; spectral cross-correlation combined many spectral lines into a fitted profile. A barycentric velocity correction removed the observer's motion.[ref]
Figure 1.
ELODIE measurement chain and synthetic radial-velocity readout
. Original schematic; the correlation profile and periodic signal are synthetic. Details.
Why can a spectrograph measure a Doppler shift much smaller than one spectral resolution element? Resolution concerns separating neighbouring features, whereas locating the centre of a known profile uses information across that profile and across many spectral lines. For a chosen example, at a recession velocity of gives
At , one spectral resolution element corresponds to , about times larger. A well measured centre can move by a small fraction of that width. More photons and more useful spectral lines improve the estimate, but do not remove wavelength calibration errors or stellar activity.
A simple mathematical picture of spectral cross-correlation makes the readout concrete. Define , with fixed reference wavelength , and let be continuum-normalized line absorption. For small velocities, a common Doppler shift approximately translates . A positive absorption mask then gives
If , the maximum occurs at ; a convention correlating the received observed radiative flux instead produces a dip. A fitted correlation centre is an effective collective line position, not a claim that each individual spectral line has been resolved into a narrower feature. The lamp tracks instrumental drift, while the barycentric velocity correction removes the observer's changing line-of-sight velocity; neither removes changes in the star itself.
Grism Created 2026-10-18 Updated 2026-11-05
A grism combines an optical prism with a diffraction grating. Their angular deviations can be chosen to cancel at a selected wavelength, while neighboring wavelengths emerge in different directions. This lets an instrument introduce spectral dispersion with approximately straight-through propagation at its design wavelength.
Inserting the grism into an imaging beam turns compact object images into dispersed optical spectra. The cancellation is wavelength-specific and order-specific: overlapping spectra and other diffraction orders remain potential sources of confusion. An optical filter can restrict the recorded band.
Wide Field Camera 3 Created 2026-10-25 Updated 2026-11-05
The Wide Field Camera 3 is an instrument on the Hubble Space Telescope with separate ultraviolet/visible and near-infrared channels. Its grisms disperse light onto the detector without an entrance slit, allowing a time series of stellar spectra during an exoplanet transit. The near-infrared channel uses two grisms covering different intervals; their combined coverage is broader than that of either alone.[ref]
A spectral channel yields a light curve, and its fitted exoplanet transit depth contributes one interval of the exoplanet transmission spectrum. The resulting molecular bands can constrain water and the atmospheric scale height, subject to exoplanet clouds and reference-pressure degeneracy in transmission spectroscopy. Because the stellar photons dominate, stability and calibration are as important as collecting light.