A passive dendritic cable models a uniform dendrite with axial electrical resistance, membrane leak and membrane capacitance, excluding active ion channels. Let be axial electrical resistance per length, membrane electrical resistance times length, and membrane capacitance per length. For voltage deviation from the leak reversal potential, electric charge conservation gives the partial differential equation is imposed inward electric current per length. Units are , and , so is a time and a length. On a source-free semi-infinite cable with imposed and as , the steady state isDifferentiate twice to verify the ordinary differential equation . At , the amplitude is of the boundary amplitude. This is a stationary attenuation law, not the complete waveform of a brief EPSP. Transient passive spread also broadens and delays responses. Finite ends, branch points and the soma's load alter the solution; distance alone cannot specify every real synaptic potential.[ref]