The solid electrolyte conducts oxide ions. Equilibrating oxygen at the two interfaces couples one molecule to four electrons. Taking the positive measured electromotive force as the air-reference potential relative to the Ni/NiO side, the Nernst equation isAssume air at one bar with , pure solid phases of unit thermodynamic activity, and . For the reaction normalized to one mole of oxygen,The negative sign is physically consistent with a strongly reducing Ni/NiO equilibrium relative to air. Using the supplied and givesThe tabulated free energies are per mole of , not per mole of NiO. Values normalized to one mole of NiO would be half as large. A reliable oxygen concentration cell measurement requires reversible interfaces, calibrated uniform temperature, a known reference oxygen pressure and predominantly ionic rather than electronic conduction through yttria-stabilized zirconia. Air is not pure oxygen: dropping the term changes the inferred entropy.
Approximate the reaction enthalpy and entropy as constant over the measured interval, so . A linear least squares fit of all three free energies against temperature givesand henceThe negative entropy change is reasonable because oxygen gas is incorporated into solids. The fit residuals are , so the data support this approximate straight-line description. Extrapolating its intercept to zero temperature is a way of estimating a constant local enthalpy, not evidence that the heat capacities vanish or that the same phases persist to zero temperature. More temperatures and repeated heating/cooling measurements would test curvature and equilibration.