For a long air-cored solenoid, Ampère's law applied to a rectangular loop running inside and outside the winding gives , with the external magnetic field negligible away from the ends. Hence along the winding axis, where . Each turn links magnetic flux with , so the total magnetic flux linkage is . It follows thatHere , and , so andThe value uses the stated long-solenoid approximation and ignores end corrections and winding resistance.