Let . For the temperature-dependent latent heat,
Keeping the latent heat of vaporization fixed changes only the upper branch to
Both curves fall from as , pass through at the triple point, and are convex. At the triple point there is a corner because the latent heat changes from to . Their right-hand slopes there agree. Above the triple point,
The variable-latent heat curve lies above the fixed-latent heat curve: its downward slope has smaller magnitude at every . It reaches a horizontal tangent at , whereas the fixed-latent heat curve is still descending. Both limiting ordinates are finite; this model gives and . These are extrapolations of the stipulated model, not accurate water liquid-gas critical point data. Extending the variable branch beyond would give negative latent heat and is physically inadmissible.
Figure 1.
Integrated saturation curves for fixed and temperature-dependent latent heat
. Details.

Articles by others on the same topic (0)