Laser relaxation oscillation 2026-10-25
Small perturbations of a class-B laser exchange excitation between the upper-state population and cavity photon number. Linearization about a four-level lasing state gives . Its damped oscillation frequency is . Long population lifetime compared with photon lifetime permits underdamped relaxation.
A laser relaxation oscillation is the damped exchange between stored upper-level excitation and intracavity photon number after a small perturbation of a lasing steady state. Extra photons increase stimulated depletion of the upper level; the resulting smaller gain then reduces the photon population. Pumping subsequently replenishes the inversion, so the two populations overshoot their equilibrium values before damping settles them.
Laser spiking is the corresponding large-signal sequence of intense output pulses, often during switch-on. Excitation first accumulates while the optical field is small. Once gain exceeds loss, rapid stimulated emission releases this stored energy in a spike, depleting the inversion below threshold. Recovery can produce further spikes. This is distinct from an externally imposed Q-switching cycle, although both draw on stored excitation.
Many solid-state gain media have upper-state lifetimes far longer than the cavity photon lifetime. The optical polarization relaxes rapidly, leaving the two slow rate-equation variables of a class-B laser. A long-lived population reservoir and a much faster photon response make underdamped recovery and pronounced startup spiking common. The criterion and frequency follow from the linearization in part c; they are not universal consequences of the word “solid-state”.
The intended quantity is , the threshold population inversion density of the cavity after switching to low loss. At this value stimulated gain exactly balances the photon-loss rate:Above threshold a nonzero seed grows; below threshold it decays. The unstarred in the subpart is shorthand for the starred threshold quantity in the displayed equations, rather than a different total atomic population. The photon lifetime fixes the photon-density loss rate .
In Q-switching, hold the optical resonator's quality factor low while pumping builds population inversion, then rapidly reduce the loss. The stored excitation produces a large optical gain, the intracavity light intensity grows, and stimulated emission depletes the population inversion until the optical gain falls below the laser threshold. The resulting optical pulse is a transient discharge of stored excitation.
Its duration depends on the high-quality factor photon lifetime, initial population inversion, saturation dynamics and switching time. For example, a simple laser rate equation model iswhere is intracavity photon number, is the available inversion in compatible units, is the pump rate and is the photon lifetime. During the short discharge, pumping and upper-state decay can often be neglected. The build-up and depletion rates determine the width; there is no universal equality between the width and . The initially stored energy and the output coupling also matter. Typical Q-switching produces nanosecond-scale optical pulses.
Photon lifetime 2026-10-25
The photon lifetime is the exponential decay time of stored energy in an unpumped optical cavity. If a round trip of duration retains an energy fraction , then and the quality factor is . Field-amplitude decay takes twice this time. Output coupling contributes to the loss as well as absorption and scattering.
Q-switching 2026-10-24
Q-switching creates a short high-energy optical pulse by first storing population inversion while an optical cavity has high loss, then increasing its quality factor so that stimulated emission rapidly extracts the stored excitation. Its duration depends on photon lifetime, excess optical gain, inversion depletion and switching time; it is not fixed by a universal time-bandwidth equality.