Bone scintigraphy Created 2026-10-24 Updated 2026-11-05
Functional imaging of bone-seeking tracer uptake with a gamma camera or single-photon emission computed tomography. Uptake patterns can reveal abnormal bone turnover.
Computed tomography Created 2026-10-14 Updated 2026-10-20
Transmission measurements determine line integrals of an absorption coefficient after taking the logarithm of incident intensity divided by transmitted intensity. Under the ideal straight-ray model, these measurements are a Radon transform; filtered backprojection reconstructs a planar slice. Angular coverage, calibration and noise control matter because differentiating measured projections amplifies high frequencies. In contrast, single-photon emission computed tomography reconstructs an emitting source through a possibly attenuating medium.
Medical imaging Created 2026-10-24 Updated 2026-11-05
Methods that infer internal biological structure or function from measured signals. Computed tomography, positron emission tomography and single-photon emission computed tomography use different signal-generation and reconstruction physics.
In single-photon emission computed tomography, the unknown is an emitting source, rather than the absorption coefficient reconstructed by transmission computed tomography. Photons emitted at different points on the same ray are weighted by their probability of surviving the path to the detector. If the known attenuation is and the detector is at the positive end of the ray, the data are an attenuated Radon transform
The directional transport equation is with zero incoming intensity. An integrating factor derives this attenuation weight. The same complexification, boundary-value and jump strategy gives spectral reconstruction of an attenuated Radon transform when attenuation is known. The unattenuated inverse from part (d) applies directly only when ; for nonzero attenuation the weighted jump and inverse must be used. This distinction allows emission imaging of the source without confusing it with reconstruction of the absorbing medium.
Keep the coordinates and operator from part (a). The attenuation is known, and the source is to be reconstructed. Put and . The directed forward attenuated Radon transform, for a detector at the positive end of the line, is
This weight accounts for absorption from each emission point to the detector. It is also derived by solving the real transport equation with zero incoming intensity: its outgoing limit is . In particular reversing the line direction generally changes the measurement. The pair reconstructs from full directed data and known ; it does not infer both unknown functions from the same data.
We must specify the sign convention for the projectors. Use the Hilbert transform and the signed Cauchy boundary operators
Then , and the positive idempotent projectors are and . This is the signed boundary-value convention in the given limits of . To express everything with ordinary complementary projectors, one may instead write , . The given limits become
Both depend on the transverse coordinate and direction but are constant along .
The equation supplies an integrating factor:
where is the inverse of unattenuated complex transport, normalized to vanish at spatial infinity. To see the normalization and analyticity rather than assume them, let . The complexified transport Cauchy kernel is
In the rotated coordinates, . The identity and the Jacobian prove with exactly this normalization. The denominator cannot vanish for nonzero real off the unit circle. The kernel is analytic separately inside and outside that circle, is at zero and at infinity. Thus and the displayed have the corresponding spectral behavior for the smooth decaying data. In particular at infinity and is bounded, indeed , at zero.
The limiting unattenuated inverse on any smooth decaying input is
One may verify this directly in the rotated Fourier variables: has multiplier , so its inverse has a pole at . As , the positive transverse frequencies have the negative tail primitive and the negative transverse frequencies have the positive past primitive; for these allocations reverse. Splitting with the Fourier projectors yields exactly the two formulas above. Applying them to reproduces the assumed limits of and checks the signs.
Now apply the same limiting inverse to . Because are independent of , its line integral is , while its tail is . Hence
The unknown incomplete line integral cancels in their difference. All remaining quantities are obtained from the measurements and known attenuation:
Each projection acts in at fixed , before evaluating and . Pulling a transverse-dependent exponential outside a projector would be incorrect.
The sectionally analytic therefore solves an additive Riemann-Hilbert problem on the counterclockwise unit circle, with the plus value inside. The normalized Cauchy integral formula is
The Sokhotski–Plemelj theorem gives its jump; boundedness at zero and decay at infinity make it unique by the Liouville theorem. Its expansion at infinity is
Substitute into the original equation. The part contributes at order one, the reciprocal derivative and vanish at that order. This derives the projection formula for inverse attenuated Radon transform:
Together with the boxed forward transform this is the requested pair. The derivation uses no small-attenuation approximation. For smooth compactly supported data the operations above are justified directly; sufficient integrable decay permits the same limiting construction.
As a normalization check, set . Then , and . Since the line transform is independent of and , the formula reduces to
the full-angle inverse Radon transform. For the radial Gaussian , and , so the reconstructed value at the origin is , checking the factor.
In single-photon emission computed tomography, represents the internal emission density, the known absorption coefficient and the directed detector counts. Each path integral weights a source point by its survival probability to the detector. Thus the attenuated Radon transform is the forward measurement model and its derived inverse reconstructs the emission distribution, providing the mathematical basis of SPECT.
The liver has a substantial normal range of size, determined by age, body dimensions, nutritional state and its variable contents; there is no universal absolute minimum and maximum valid for every healthy person. One must also distinguish true organ volume from the position of its lower border, which moves with the respiratory diaphragm during breathing.
An ordinary adult liver is on the order of 1.5 kg and roughly a few percent of body mass, but neither figure is a diagnostic boundary. As an explicitly modern example, an autopsy study of adult men reported a mean hepatic mass of 1561 g and observed values from 838 to 2584 g in its selected population. Those are sample observations, not a declaration that every liver inside those limits is healthy or that every one outside is diseased. A newer large-sample study similarly found an association of liver mass with body mass; much of an apparent sex difference disappears when body size is taken into account.[ref][ref]
Age changes the proportion as well as the absolute size. The fetal and infant liver is relatively large; the adult organ is smaller in proportion to the whole body. Its fetal role in haematopoiesis and subsequent changes of growth and function make an adult mass standard inappropriate for an infant. Constitutional body size and normal anatomical shape also vary: a long lower projection is not necessarily the same thing as an enlarged total organ.
Reversible differences within one person arise because the liver is a store and a vascular organ:
  • Glycogen is accumulated after suitable feeding and mobilized during fasting and exercise. Its storage is associated with water, so changing glycogen stores changes more than the dry mass of the stored glucose units.
  • Hepatic lipids and their turnover also contribute to variation. This does not make substantial hepatic steatosis a normal consequence of every meal or justify treating pathological fatty enlargement as physiological.
  • The amount of blood contained in the hepatic sinusoids and larger vessels can change with circulation and posture. Physiological vascular filling must be distinguished from persistent congestion caused by heart failure.
  • Hydration and longer-term nutritional state influence the organ and its stores. Severe wasting or a persistent progressive enlargement requires a different explanation from a reversible difference between standardized fed and fasted observations.
A meal therefore changes hepatic activity and splanchnic blood flow without requiring a large immediate increase in total liver volume. In a modern paired study of 20 healthy volunteers, single-photon emission computed tomography before and after a standardized meal showed a nonsignificant 1.5% decrease in estimated liver volume. The authors judged the change to be within methodological error. This is a useful check against assuming that greater digestive activity proves gross swelling.[ref]
The experimental approach is to compare like with like: specify age and body mass, use a fixed interval after food, standardize hydration, posture and respiratory phase, and distinguish a volume measurement from a palpable edge or a single linear dimension. Magnetic resonance imaging can measure volume while magnetic resonance spectroscopy measures glycogen or lipid signals; the two observations answer different questions. The size of an excised organ additionally depends on how much blood remains in it. The physiological point appropriate to the 1866 question is reversible variation with growth, alimentation and vascular filling. Modern imaging results refine that point; they are not numerical standards that the historical exam could have expected.
Single-photon emission computed tomography detects individual gamma rays from a tracer. Mechanically collimated gamma cameras acquire projections from multiple angles for tomography. The collimator discards most emitted photons, creating a strong sensitivity–spatial resolution trade-off.
Positron emission tomography uses a Positron-emitting tracer. The emitted Positron travels a short distance before electron-positron annihilation produces an approximately back-to-back photon pair. Coincident detection in a detector ring defines a line of response, giving electronic collimation and greater detection efficiency; time-of-flight PET further constrains position along that line. The positron range, non-collinearity, detector size, scatter and accidental coincidences limit spatial resolution and quantification. In both hybrids, computed tomography supplies anatomy and an attenuation correction map, with attention to registration and respiratory motion.[ref]