The time above threshold for an RC-filtered rectangular pulse is the separation of its rising and falling threshold crossings, rather than the applied pulse duration. In the relaxed first-order model, put with and . The parent crossing calculation gives
This excludes comparator propagation dynamics and uses the same threshold on both edges. A Schmitt trigger with unequal switching thresholds needs a different formula.
The positive-width relation can be inverted exactly:
Its derivative is . Thus a measured positive determines a unique input duration under the stated model. A zero-width observation does not: all rejected durations have that same outcome.
For an original example, take , and . The output remains above threshold for about , longer than the input pulse because of its decaying tail. Substitution into the inverse relation recovers .
For long pulses, tends to . It is positive below a half-height threshold and negative above one. At exactly half height, for every finite accepted pulse, with the difference tending to zero for long pulses. Consequently a measured above-threshold width cannot be equated to the input width without the threshold and filter model.
A pulse-generator/oscilloscope comparison can record both widths while varying threshold. The measured RC decay should be checked independently, using the natural-response method in the primary MIT laboratory.[ref] Initial residual charge, hysteresis, and different rising/falling comparator delays alter the observation; the algebra above only inverts the ideal capacitor waveform.