Cardiac apex 2026-11-05
The cardiac apex is the pointed inferior end of the heart, formed mainly by the left ventricle. It lies toward the patient's left and supplies a useful endpoint for describing the cardiac long axis. The anterior interventricular sulcus and posterior interventricular sulcus approach this region along the ventricular surface.[ref]
The cardiac apex is an anatomical landmark, not a fifth chamber or an opening through which blood leaves. Blood flow from the left ventricle passes through the aortic valve; a pointed chamber outline does not indicate the outlet. This distinction is helpful when translating a simplified heart-shaped drawing into actual chamber connections.
A concrete orientation exercise begins with an anterior view of a specimen: identify the cardiac apex, follow the anterior interventricular sulcus away from it, then locate the coronary sulcus. These landmarks relate the ventricular tip, ventricular boundary and atrial–ventricular boundary. Right and left refer to the patient's anatomy, so a frontal illustration viewed face-on reverses them relative to the viewer.
The distinction between a landmark and a measurement also matters for the apical impulse. A motion detected at the chest surface is an observation of transmitted movement, whereas the cardiac apex is a location on the heart. Similarly, an echocardiography image needs an identified viewing direction: distance from an image edge is not an anatomical definition of the apex. A shared anatomical reference makes different views comparable.
Cardiac image foreshortening 2026-11-05
Cardiac image foreshortening occurs when a cardiac view represents a shorter apparent base-to-apex extent than the intended anatomical chamber length, often because the imaging plane misses the true cardiac apex. It can create an apparently thick false apex and affect derived ejection fraction and deformation measurements.
A primary echocardiography study acquired optimal and deliberately foreshortened views in 72 participants using a GE Vivid E9 system. The altered acquisition window was one rib-space above the optimal window; two analysis systems were used to compare derived quantities.[ref]
Impact of apical foreshortening on deformation measurements: a report from the EACVI-ASE Strain Standardization Task Force by Serkan Ünlü and others. Abstract, Aims and Methods and results
This tests acquisition geometry while keeping the participant the same, rather than interpreting every shorter-looking chamber as a biological change.An original ellipsoid model distinguishes a missed apex from a simple projected length. Letwith the true cardiac long axis along . The central long-axis plane includes both axial tips and has full length . A parallel offset plane instead intersects an ellipse whose apparent axial extent isAt , . A 10 cm true extent therefore appears as 8 cm in this model even though the slice was translated rather than rotated. Its apparent tips are not the original chamber tips.
This model is a geometrical explanation, not a clinical correction formula. A shorter outline can alter measured volume differently at end-diastolic volume and end-systolic volume; the ejection fraction error need not follow the length error by one fixed percentage. Consistent anatomical landmarks and independent views help distinguish actual chamber shape from the chosen section. Improving the repeatability of an outline inside an incorrect plane does not recover anatomy that was never acquired.
A parallel cardiac slice can miss the true apex
. Original sections of an ideal ellipsoid with axial semiaxis 5 cm and transverse semiaxis 2 cm. The central plane has full length 10 cm; a parallel plane offset by 0.6 times the transverse semiaxis has length 8 cm. Dashed outline shows the central section for comparison. Synthetic geometry, not patient data. Details. Cardiac long axis 2026-11-05
A cardiac long axis is a base-to-apex direction used to describe the heart or a specified ventricular chamber. In left-ventricular imaging it is commonly planned through the cardiac apex and the center of the mitral valve. It is a chamber-based anatomical reference, not necessarily the vertical direction of a patient's body or an image display.
The primary cardiovascular magnetic resonance imaging protocol specifies connected two-chamber, four-chamber and short-axis planning from anatomical landmarks.[ref]
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update by Christopher M. Kramer and others. General techniques, Left ventricular structure and function, items 3 and 6; Figures 1–3
A long-axis image plane contains the chosen cardiac long axis; the corresponding cardiac short axis describes a transverse direction or view. Different planes can contain the same long-axis line while displaying different walls and neighboring chambers.An original vector construction makes the distinction precise. Let be the apex position and a chosen basal reference point. Thenis the axial unit vector. A displacement has axial component and transverse component . The line alone does not determine how the transverse coordinates are rotated around it.
This geometry matters for cardiac image foreshortening. In a simple projection model, a length tilted by out of the display plane projects to . A 10 cm length tilted by appears about 8.66 cm long. This is a geometrical illustration, not a correction formula for a tomographic slice: a slice may miss the true apex rather than project it. Consistent landmark selection is therefore part of meaningful comparisons of cavity shape, motion and volume.
Cardiac short axis 2026-11-05
A cardiac short axis is a transverse reference direction or imaging view relative to a specified cardiac long axis. For left-ventricular imaging, a short-axis plane is planned across the chamber rather than through its base-to-apex length. The chamber and anatomical landmarks must be specified; a patient's horizontal body plane is not automatically a cardiac short axis plane.
A primary cardiovascular magnetic resonance imaging protocol plans short-axis images using linked long-axis views and covers the ventricle from base to apex.[ref]
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update by Christopher M. Kramer and others. General techniques, Left ventricular structure and function; Figures 1–2
A cardiac short-axis stack turns successive cavity outlines into volumetric information.For an original geometrical construction, let be the unit vector along the chosen cardiac long axis. A transverse plane through satisfiesParallel planes at different axial positions sample different portions of the ventricle. With measured cavity areas and represented slice thicknesses , a simple volume estimate is .
An oblique slice also illustrates a useful caution. An ideal circular cylinder cut at angle away from its perpendicular section has an elliptical cross-sectional area . At this is about larger. This does not prove that an entire consistently acquired oblique stack overestimates volume: integrating all areas with the correct normal spacing and complete coverage still recovers volume. Orientation, spacing and coverage must be treated together. The major practical question is whether the chosen stack and image segmentation represent the complete intended cavity, not whether one slice happens to look circular.
Cardiac short-axis stack 2026-11-05
A cardiac short-axis stack is a series of images across a cardiac chamber at successive positions approximately transverse to its cardiac long axis. In ventricular volumetry, the series must cover the intended cavity from its basal boundary toward the cardiac apex. A primary cardiovascular magnetic resonance imaging protocol specifies linked long-axis planning and short-axis coverage.[ref]
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update by Christopher M. Kramer and others. General techniques, Left ventricular structure and function; Figures 1–2
The stack supplies a spatial sum rather than a single diameter. Let be the segmented cavity area in slice at phase , and let be the represented distance along the stack normal. A basic approximation isAll areas in a given sum must refer to a compatible phase of the cardiac cycle. Image segmentation, slice coverage and phase matching are separate inputs to the volume estimate.
An original example uses four representative areas of 2, 6, 10 and 6 cm, each assigned 1 cm of axial extent. Their represented volume is 24 cm, or 24 mL. Omitting the basal 6 cm contribution reduces the result to 18 mL without changing the tracing quality of the other slices. If slice thickness is 0.8 cm but center spacing is 1 cm, the numerical integration convention must also account for the intervening extent; treating thickness and represented spacing as interchangeable changes the estimate.
Phase mixing causes a different error. An area from one slice near end-filling and another near end-ejection do not generally describe a cavity that existed at one time. A stack can therefore be complete spatially yet inconsistent temporally. With correctly matched phases, the derived end-diastolic volume and end-systolic volume can be used for stroke volume and ejection fraction; those formulas do not repair missing anatomy or mismatched acquisition phases.
Christopher M. Kramer 2026-11-05
Christopher M. Kramer is a cardiologist whose research uses cardiovascular magnetic resonance imaging to assess the heart. His University of Virginia profile identifies cardiovascular imaging as an area of expertise.[ref]
Christopher M. Kramer profile at UVA Health. Bio & Overview
He is the first author of the 2020 primary protocol document specifying standardized cardiovascular magnetic resonance imaging acquisitions.[ref]One concrete contribution of such a protocol is to make image geometry reproducible. Its left-ventricular procedure links the cardiac apex, mitral valve center, cardiac long axis views and a cardiac short-axis stack.[ref]
Standardized cardiovascular magnetic resonance imaging (CMR) protocols: 2020 update by Christopher M. Kramer and others. Left ventricular structure and function, items 3 and 6; Figures 1–3
The geometry determines which anatomy is acquired before an analyst draws a cavity boundary.An original example explains the measurement consequence. A volume reconstructed as depends on both the cavity areas and the represented slice thicknesses. If ten slices each have area 8 cm and represented thickness 0.8 cm, the estimate is 64 mL. Omitting one such slice loses 6.4 mL even if every retained boundary is traced perfectly. Standardized coverage and phase selection therefore address errors that cannot be removed merely by improving image segmentation on the available slices.
The documented protocol work connects acquisition choices to interpretable measurements of chamber structure and function. It provides technical procedures and reference geometry; the arithmetic example here illustrates their purpose rather than reporting a result from that document.
Mitral annular excursion 2026-11-05
Mitral annular excursion is displacement of the mitral annulus over a specified part of the cardiac cycle. A commonly used longitudinal observation follows an annular landmark along the cardiac long axis during ventricular systole. The reference position, direction and endpoints are part of the measurement; displacement is distinct from annular area or leaflet coaptation.
The measurement question can be written explicitly. For a fixed unit axis and landmark position , defineAn original 10 mm displacement viewed along an axis tilted by projects to mm. Thus changing the observation direction changes the reported excursion even for the same motion. A single landmark also need not represent every part of a deforming mitral annulus.
A primary human study used cine magnetic resonance imaging, measuring longitudinal displacement in long-axis views and stroke volume in short-axis views. Its model combined displacement with a ventricular short-axis area.[ref]
Atrioventricular plane displacement is the major contributor to left ventricular pumping in healthy adults, athletes, and patients with dilated cardiomyopathy by Marcus Carlsson and others. Abstract, Methods
In an original rigid-piston approximation, area moving axially by sweeps volume . Areas 20 and 40 cm paired with displacements 1 and 0.5 cm both give 20 mL. Smaller excursion need not imply a smaller geometric swept volume when area differs; this model area is not automatically the mitral opening area.A complementary experiment by C. Carlhäll and colleagues implanted markers around the mitral annulus and ventricular wall in six sheep. Biplane fluoroscopy reconstructed three-dimensional marker motion, and tetrahedron-based estimates assessed annular contributions to filling while loading and contraction were varied.[ref]
Contribution of mitral annular dynamics to LV diastolic filling with alteration in preload and inotropic state by C. Carlhäll and others. Abstract, experimental methods
This connects a displacement measurement to moving-chamber geometry. The changing boundary, surrounding deformation and blood flow must be distinguished when relating mitral annular excursion to filling or ejection.