Engineering strain is the change in a measured segment's length divided by that segment's initial length:
It is dimensionless. A segment initially long that extends by has , or one percent. The initial gauge length must match the instrument's measured extension; actuator motion can include deformation of grips and the test frame.
For a uniform stretch ratio , engineering strain is . It agrees with the small axial strain to leading order, while the logarithmic length change is . Engineering strains over successive finite stretches do not simply add: two extensions of ten percent multiply length by , giving a total of twenty-one percent. This makes the choice of reference length essential when comparing measurements taken over different loading stages.