Excitation-band selectivity in nail fluorescence corrections describes how well the detection system distinguishes transmitted illumination from light emitted by the nail plate. Selecting the illumination with a monochromator does not force every detected photon to remain in that spectral band: fluorescence can contribute at other wavelengths.
For an original linear detection model, write the transmitted and emitted spectral powers as and , where both spectral shapes integrate to one. If an optical filter has transmission and a detector has spectral responsivity , its current after subtraction of dark current is
The coefficients are spectrum-weighted responsivities, with units of amperes per watt. A selective filter can reduce while also reducing , so an uncorrected smaller current does not establish lower specimen transmittance.
For stipulated , , and , current is . Assigning all of it to transmitted illumination gives , a 1.67% relative overestimate. These chosen coefficients illustrate leakage; they are not measured filter characteristics for nails.
Emission-spectrum mismatch in nail fluorescence subtraction matters when the assumed differs from the specimen's emission. If analysis subtracts while the true coefficient is , then
At the same powers and , using instead of 0.020 leaves a positive bias. A precisely known total emitted power would not eliminate this spectral mismatch.
The historical nail-transmission experiment explicitly corrected for fluorescence.[ref] The integral above is an explanatory extension, not a reconstruction of its unpublished correction coefficients. An experimental test would characterize detector/filter response and compare detection bands while keeping illumination and collection geometry in nail-transmission measurements fixed. Spectral rejection and angular collection constrain different parts of the measurement.
Emission-spectrum mismatch in nail fluorescence subtraction is the error caused by correcting a detector reading with an assumed fluorescence spectrum that differs from the actual emitted spectral shape. Knowing total fluorescent power does not generally determine fluorescent detector current, because the detector/filter response varies with wavelength.
Let be the true normalized emission spectrum, the assumed normalized spectrum and the product of spectral responsivity and optical filter transmission. Define
For a current , subtraction of gives
Although , the response-weighted integral need not vanish. Equal total emitted powers can therefore require different corrections.
An original two-band example makes the effect visible. Suppose the effective responsivity is and in two nonoverlapping bands. If fraction of fluorescent power lies in the first band, . The assumed fraction gives , whereas the true gives . At and transmitted-band responsivity , the transmitted-power estimate is biased by . A true would be reported as after that excessive subtraction.
These are stipulated spectral shapes and coefficients, not measured nail spectra. If were constant over the entire emission band, normalization would make this particular shape error vanish. A selective system generally sacrifices that invariance to distinguish transmitted excitation light from emission. Responsivity characterization and spectral measurement must therefore accompany a proposed subtraction.
The primary nail experiment explicitly included a correction for fluorescence while measuring transmission with a monochromator, integrating sphere and photodiode.[ref] That observation motivates the distinction between emitted power and detected current; it does not specify the two-band correction model above. Fixing an assumed spectrum in software does not establish that the specimen actually has that spectrum.