The Gaunt factor is the dimensionless quantum correction to a classical free-free radiation calculation. Its weak temperature and frequency dependence modifies the approximate thermal bremsstrahlung scaling; a frequency-averaged value appears in the bolometric cooling coefficient.
For fully ionized hydrogen and helium with hydrogen mass fraction , and . With the same unit Gaunt factor for both species, thermal bremsstrahlung at fixed electron number density is multiplied by relative to pure ionized hydrogen. The factor is one for pure hydrogen and two for pure helium.
Thermal bremsstrahlung arises from electron acceleration in ion Coulomb fields. For a thermal plasma its optically thin spectral emissivity has the dependence
The exponential high-energy slope helps constrain temperature in X-ray spectra, with composition, absorption and other emission components included. At radio frequencies with , the thin spectrum is much flatter and does not alone determine a unique temperature; the Gaunt factor supplies a weak frequency dependence.
For an approximately isothermal layer, radiative transfer gives . Radio free-free opacity scales approximately as , where the hydrogen-plasma emission measure is . A resolved optically thick brightness temperature approaches ; an unresolved filling factor lowers the observed value. The turnover between thin and thick regimes helps constrain emission measure.
An angular extent and distance give a physical size, and an assumed geometry supplies a line-of-sight depth. Combining that depth with emission measure estimates an rms density, . Clumping, filling factor, composition and unknown depth preserve a density-depth degeneracy of free-free radiation. These measurements constrain different combinations of temperature, density and size rather than independently fixing all three without assumptions.
thermal bremsstrahlung is continuum radiation from electrons accelerated in ion electric fields. For Maxwellian electrons,
At high frequency the exponential cutoff constrains ; X-ray fitting must also model foreground absorption, line emission, detector response and possible multitemperature or nonthermal components. At radio frequencies, , an optically thin free-free spectrum is almost flat, with the weak frequency dependence set mainly by the Gaunt factor.
For pure ionized hydrogen, radio free-free opacity gives
The turnover constrains emission measure; a resolved, optically thick source has brightness temperature approaching . An unresolved source has an unknown beam filling factor, so its observed brightness need not equal its electron temperature. Angular size and an independent distance give a geometric depth ; a uniform model then yields . Clumping instead measures a density-squared average, not the mean density.[ref]
A free-free spectrum alone does not uniquely determine density and size. The density-depth degeneracy of free-free radiation is explicit: for a resolved uniform column, , leaves both emissivity-integrated brightness and optical depth unchanged at fixed temperature. With independent SZ information and known , the electron column is ; then
These equalities require consistent composition and geometry, and uniform density and temperature. Relating to angular extent can give distance; asphericity and the gas clumping factor are important limitations of this combined cluster method.
An electron accelerated in an ion's Coulomb field emits bremsstrahlung. Both electron states are unbound, giving free-free radiation rather than a discrete bound-state line. Averaging over a Maxwellian electron distribution gives an optically thin spectral emissivity with dependence
Here depends on the emissivity convention, and the Gaunt factor supplies the quantum correction. No numerical emissivity normalization is needed for these diagnostics. For a mixture, sum over ion species. The bolometric emissivity is proportional to with a frequency-averaged Gaunt factor. Thermal electron speeds control the spectrum while the encounter rate supplies its density-squared dependence.
temperature can be measured from the high-energy exponential cutoff at photon energy of order , provided the spectrum spans that turnover and foreground absorption and nonthermal contamination are modelled. At radio frequencies , the exponential is nearly one, so the optically thin continuum is a poor thermometer by slope alone. Kirchhoff's law, , and the Rayleigh-Jeans law give for an isothermal thermal plasma. The transfer solution is
in the radio limit. A resolved optically thick region therefore measures its electron temperature through brightness temperature, if it fills the beam. The turnover between thick and thin emission constrains the line-of-sight emission measure for a hydrogen-dominated fully ionized plasma. In the thin regime , rather than . The slowly varying Gaunt factor gives a nearly flat optically thin radio flux-density spectrum, in contrast to the thick limit at fixed projected area.[ref]
To obtain density, one also needs geometry. An angular extent and independent distance give a transverse size; an assumed shape provides a depth or volume. For approximately uniform emitting gas with astrophysical volume filling factor , , so . Alternatively a measured column emission measure and assumed path length give an rms density. Clumping raises the mean squared density relative to the square of the mean: the inferred value is not automatically the mean gas density. Free-free brightness alone does not uniquely determine temperature, density and physical size. Resolved imaging, a distance, optical-depth information or an independent column-density diagnostic is needed to remove those degeneracies. Cluster SZ data are complementary because their leading signal depends on , whereas free-free emission depends on density squared. Metal lines, unresolved temperature structure, foreground absorption, synchrotron emission and background subtraction must be controlled before attributing the continuum to a single thermal component.
Thermal bremsstrahlung is radiation from the acceleration of electrons in the Coulomb force of ions. At fixed temperature, the encounter rate per electron is proportional to ion number density , and the number of radiating electrons per unit volume is . Therefore in a dilute, optically thin plasma. This is a binary-encounter rate, not a one-particle emission process.
For a fixed encounter geometry, the ionic electric field and hence the electron acceleration are proportional to ionic charge . The Larmor formula is quadratic in acceleration, giving at fixed species number densities. The dimensionless Gaunt factor corrects the simple classical result for the detailed quantum scattering and radiation calculation, after averaging over the thermal electron distribution. It depends on frequency and temperature and, in a more complete notation, ionic charge.
For , expand the exponential in the thermal free-free emissivity:
The energy emitted per unit frequency is therefore approximately flat, with the weak Gaunt factor dependence superposed. At these low photon energies, most of the thermal electrons can participate in emission; there is no exponentially small population threshold.
For , the spectrum turns down approximately as , apart from the Gaunt factor. Conservation of energy requires an emitting electron to supply at least . The high-energy tail of its Maxwell-Boltzmann distribution is exponentially rare, which produces this cutoff.
“Flat” refers to , an energy spectrum per unit frequency. The emitted photon number spectrum instead contains , while energy per logarithmic frequency interval is . At sufficiently low frequency the plasma can also become optically thick to free-free absorption; the given optically thin emissivity is then not the escaping spectrum.
Neglect electron mass and nuclear binding corrections when converting mass density into hydrogen and helium number densities. With ,
The thermal free-free emissivity adds over ion species with weights . Consequently
With each Gaunt factor set to one, the mixture has
At fixed , pure hydrogen gives the composition factor , and pure helium gives . The latter check follows independently from and ; simply replacing by an average charge would lose this weighting.