The intrinsic frequency is the frequency observed in a frame moving with the basic flow. For a wave of frequency and horizontal wavenumber in a uniform current , it is .
A critical level is a height at which the intrinsic frequency of an internal gravity wave vanishes. For finite positive buoyancy frequency, its local vertical wavenumber diverges as . The inviscid Taylor–Goldstein equation is singular there; viscosity, diffusion or nonlinear wave breaking can regularize the resulting small scales.
For upward internal gravity waves, let be constant. Combining with the monochromatic internal-wave overturning criterion gives . Near a critical level the onset balance is . This is compatible with ; it fixes the overturning point rather than redefining the dispersion relation.
For and constant positive buoyancy frequency, the critical height is . A stationary upward ray approaches it with vertical group velocity proportional to , requiring infinite ideal ray travel time. Large gradient Richardson number can preserve the short-wavelength WKB approximation, but parcel-displacement amplitude grows and eventually invalidates linearity.