Reactive volt-ampere 2026-11-05
The reactive volt-ampere, conventionally called the var and written with symbolvar, expresses reactive power. The official SI text notes the IEC's special name and states that its coherent unit is identical to the volt ampere. The name identifies the reactive quantity; it is not a different base-unit dimension.[ref]
In sinusoidal steady operation with RMS magnitudes and relative phase ,
Thus100V RMS,2A RMS and a lagging phase with give120var. Under the same passive and phasor conventions, a leading phase of equal magnitude gives−120var. The signed value describes exchange phase rather than negative dissipated heating. The prefix relation is .
A reactive-power value is also not an amount of stored energy in joules. For an ideal inductor in sinusoidal steady operation,
For an original200var example at50Hz, mean stored energy is and peak stored energy is twice that. The average absorbed active power is nevertheless zero in the ideal inductor. The primary circuit treatment derives this separation between energy storage and mean dissipation.[ref]
In a sinusoidal100V example with , the reactive component is300var, the active component400W and apparent power500VA. Adding400 and300 as ordinary scalar powers would not give the500VA magnitude. Complex electrical power retains the phase relation needed for this combination.
Volt 2026-10-13
The volt is the SI unit of electric potential and electric potential difference: , one joule per coulomb. A positive electric charge of moved through a potential increase of gains of potential energy; the electric field does of work. [ref].
Watt 2026-10-14
The watt is the SI unit of power, one joule per second. Joule heating at transfers of energy over a time of if that power stays constant. [ref].
Weak-field Zeeman splitting Created 2026-10-18 Updated 2026-10-20
Use the leading nonrelativistic magnetic coupling for an electronic level with total angular momentum operator , and choose the axis along a uniform external magnetic field , . Write its magnetic quantum number as , so . There are possibilities from to . With Landé g-factor , the first-order shift is
Here is the magnitude of the electron electric charge, its mass, the Planck constant, and the Bohr magneton. Both and are dimensionless; with measured in tesla and in joules per tesla, is in joules. The photon frequency shift is in hertz, not angular frequency; indices denote upper and lower levels. NIST states this weak-field convention and its orbital/spin assumptions explicitly.[ref]
The sign follows directly from magnetic dipole potential energy. Within this electronic multiplet, the projected magnetic dipole moment is . Therefore has the displayed positive coefficient. Subtracting the shifts of the two levels and using photon energy gives the transition formula. For the orbital case, gives the same leading frequency spacing as the classical charged oscillator. This explains the historical sensitivity to charge divided by mass; the quantum state derivation here is modern.
“Weak” compares interaction energies: mixing with neighbouring fine structure levels must be small, so remains a useful quantum number. The formula keeps the term linear in and neglects quadratic shifts. It also omits hyperfine structure; if that is resolved and controls the coupling, the appropriate total electronic-plus-nuclear angular momentum and splitting factor must replace . Weak compared with fine structure does not automatically mean weak compared with hyperfine structure.