A bulk ferromagnet generally separates into magnetic domains. Within each domain many moments align and the local magnetization can be large, but different domain orientations partially or almost completely cancel the vector sum measured for the entire specimen. This reduces its external stray field and magnetostatic energy. Formation of magnetic domain walls costs exchange and anisotropy energy, so the actual pattern balances these costs with the reduction in stray-field energy.
A strong applied field can move domain walls and rotate moments toward a nearly saturation magnetization. When the field is removed, pinning and the sample's magnetic history determine the remanent moment. Thus a small net moment does not show that local ferromagnetic order has disappeared, or that moments within each domain are all randomly oriented. At finite temperature, thermal spin fluctuations also reduce the local ordered moment below its zero-temperature maximum even in a single-domain specimen. These two reductions—between-domain cancellation and within-domain thermal reduction—should be distinguished.