For each beam in vacuum, its magnetic field is . Write the two complex scalar contributions, including the beam splitter factor, as and . Since their electric fields are both along ,
The optical-cycle and ensemble-averaged Poynting vector is
The mean individual light intensities are equal, so
Thus energy flows along the bisector of the two beam directions, crossing a detector plane normal to . Such a sensor can in principle record the variation across its coordinate. Its actual normal energy flux is in the normalization used above; this fixed factor does not change interferometric visibility.
There is a practical resolution condition in addition to the direction of energy flow. The interference fringe spacing is very small, so direct pixels would need spacing no larger than as required by the Nyquist–Shannon sampling theorem, or optical magnification and sufficient angular aperture to preserve both incident directions. An ordinary optical camera with much larger effective pixels averages the interference fringes. The Poynting-vector argument establishes the allowed measurement geometry, not guaranteed resolution with any optical camera.

Articles by others on the same topic (0)

There are currently no matching articles.