In the long-solenoid approximation, the internal magnetic flux density is uniform, , and the external magnetic field is negligible. This follows from the magnetostatic Ampère law applied to a rectangular loop running inside and outside the solenoid. Its number of turns is and its cross-sectional area is . Each turn links magnetic flux . Therefore the flux linkage isUsing the definition of self-inductance, , givesThis neglects end leakage and winding thickness and uses vacuum permeability for the air core.
Articles by others on the same topic
There are currently no matching articles.