In the cold underdense model, 1−vg/c≃n/(2nc) and γϕ2≃nc/n=500. A relativistic electron slips through half an accelerating sinusoidal wavelength over Ld≃γϕ2λp≃8.35 mm. For Ez=E0sinϕ and injection at the start of that half-cycle, integration over 0<ϕ<π givesInjection at the field crest and acceleration only to its next zero gives half this value, about 0.51 GeV; this explains a common factor-two convention in dephasing estimates. Multiplying the peak field by the entire dephasing length is instead an upper bound, not the sinusoid's actual integral. These are ideal wave-amplitude estimates: a0<1 need not excite E0, and finite pump depletion, pulse evolution and injection physics may reduce the gain. Without a specified nonlinear wake shape, the data warrant an order-GeV cold-wave upper scale, not a unique precision maximum for an actual experiment.
ΔEmax≃4γϕ2mec2≃1.0 GeV.