The consistent matching is:
Series C stops after about six months, identifying machine 2. Its short record gives spectrum W a coarser Fourier frequency resolution. Series A resolves the annual variation but misses the changing daily phase: the regular three-day interval samples the daily oscillation at the same phase, so its daily contribution aliases to a constant. Its spectrum is Y. Machine 3 produces the half-daily-frequency alias in X, leaving D as its time series. The fully sampled two-year record B and spectrum Z agree with the supplied first row.
These identifications use the record lengths, frequency locations and sampling intervals. They do not require assuming that the plotted spectral heights have an identical normalization.
The conventional Nyquist frequency isFrequencies above this cutoff are indistinguishable from lower-frequency sampled sinusoid aliases. The Nyquist–Shannon sampling theorem requires a band limit strictly below the cutoff for general phase information: at exactly the cutoff, some phases can give zero samples. Thus hours is the conventional limiting period, with unambiguous reconstruction requiring a longer period under those sampling assumptions.
The true daily component has , above machine 3's Nyquist frequency. At sampling times days,The last sequence is also produced by a continuous cosine with frequency sampled at those same times. Hence the observed peak is the sampled sinusoid aliasIt is not evidence for an additional two-day physical temperature cycle.
The source text and its figure are inconsistent here. The plotted low-frequency maximum in W is near , rather than the printed . The original PDF shows that this discrepancy is already present in the examination, rather than introduced by transcription.
Machine 2 records only about half a year. Its first nonzero discrete Fourier transform bin is therefore atThe annual component near is below that first bin. The finite window function spreads it through spectral leakage, with a prominent first-bin contribution. This explains the plotted peak without invoking a new physical period.
A literal peak at would instead have a period of about days. Neither the two stated model frequencies nor the given sampling schedule identifies such a separate component. The interpretation above treats the printed decimal as an apparent typo; it does not silently change the stated number.
The adequately sampled record shows a yearly cycle and a daily cycle. Up to exchanging their labels,Using days per year for numerical estimates,These are angular frequencies. The corresponding ordinary frequencies are and .