The residual correction in tie-line sensitivity accounts for rotation of a fitted liquid-liquid tie line when the measured overall composition does not lie exactly on it. In independent mole fraction coordinates, set , hold a symmetric positive-definite matrix fixed, and use the interior unconstrained tie-line phase-fraction fit. With , residual , and row vectors , , its differential isThe full derivation is in tie-line phase-fraction sensitivity. The normal equation makes orthogonal to in the chosen metric; it does not make the residual zero.
For an original example, take , , and . The third mole fraction is fixed by closure. These choices giveIncreasing only the first coordinate of by predicts a phase fraction change . Omitting the correction misses the second contribution even though the fit satisfies its normal equation. A centered finite-difference recalculation as the perturbation shrinks tests this derivative directly.
This is a local sensitivity, not an uncertainty until combined with the joint input covariance matrix.[ref]
Guide to the expression of uncertainty in measurement by JCGM. §§5.1.3–5.1.4, sensitivity coefficients; §5.2.2, correlated-input propagation
The formula assumes distinct endpoints and an interior fit with fixed . A changing metric requires sensitivity of a tie-line fit to its weight matrix; a constrained boundary requires a separate local analysis. A nonzero residual can reflect composition noise or model mismatch and does not independently establish liquid-liquid equilibrium.Sensitivity of a tie-line fit to its weight matrix describes how changing the metric changes an inferred phase fraction, even when the measured compositions are held fixed. For distinct endpoints , define , and the interior unconstrained tie-line phase-fraction fitDifferentiating the normal equation , with fixed, givesThis term supplements the composition and endpoint derivatives in tie-line phase-fraction sensitivity; it is not included in their fixed-metric formulas.
For an original example, use independent mole fraction coordinates , and . With , the fitted fraction is , and . Increasing the second diagonal weight from to predictsDirect refitting gives , a change of . The small difference is the neglected higher-order term.
Two invariances clarify the result. An exactly balanced composition has and the same fraction under every positive-definite metric. Also, replacing by for positive leaves the fraction unchanged: the scalar rescaling invariance of a tie-line weight matrix follows from cancellation in its ratio. The differential agrees because .
If for a composition covariance matrix, its perturbation is to first order. Uncertain fitted weights can therefore add sensitivity, with correlations to the composition measurements retained in the measurement model. This is an application of the guide's general sensitivity-coefficient framework, not a tie-line formula quoted from it.[ref]
Guide to the expression of uncertainty in measurement by JCGM. §5.1.3, derivatives of the measurement model; §5.2.2, correlated inputs
Boundary-constrained fits and coincident endpoints need separate treatment.Scalar rescaling invariance of a tie-line weight matrix means that multiplying every fit weight by the same positive number leaves the fitted phase fraction unchanged. Let endpoint compositions and overall composition be expressed in independent mole fraction coordinates. With , a fixed symmetric positive-definite matrix defines the tie-line phase-fraction fit by minimizingFor , . Multiplication by a positive constant preserves every comparison between objective values, so the sets of minimizers agree. The proof also applies when the same constraint is imposed in both fits.
For distinct endpoints, the unconstrained formula makes the cancellation visible:The differential in sensitivity of a tie-line fit to its weight matrix agrees: for a perturbation , its numerator is by the fit's normal equation. Thus the scalar direction is insensitive even when the residual is nonzero.
In an original example, take , , and . The remaining composition coordinate is fixed by closure. These values giveReplacing by gives the same fraction, although the minimum objective increases from0.00072to0.00504. Changing only the second diagonal weight from4to7 instead changes the fitted fraction to0.640625. Relative weights determine the geometry; their common multiplier does not.
Point-estimate invariance does not by itself establish invariance of physical measurement uncertainty. Merely rewriting the same objective with leaves propagation through the same measured-input covariance matrix unchanged. If instead represents absolute precision and asserts a genuinely different covariance , that is a different noise model. With exact endpoints, the linear-model variance then decreases by a factor . The measurement model and covariance interpretation must be stated.[ref]
Guide to the expression of uncertainty in measurement by JCGM. Sections 5.1.3 and 5.2.2, model sensitivities and covariance propagation; tie-line result derived here
Articles by others on the same topic
There are currently no matching articles.