Past exam of the mathematics course of the University of Cambridge 2017 iii Paper 338 3 c i Solution Created 2026-10-03 Updated 2026-10-06
Let . After offset subtraction, each summed image has mean analogue-to-digital units per detector pixel. For a constant detector conversion gain and independent Poisson distribution detected counts, : summing independent frames adds both their means and variances. Here is the mean of the sum, not one frame.
Write , . At high counts, the delta method gives . Independence therefore givesThus the formula is a high-signal gain estimation from flat-field ratios, not an exact identity for a ratio of random variables. A Poisson distribution denominator can even be zero at low counts. The exposures must be linear and unsaturated, offsets removed, and read noise negligible. Being close to saturation increases the signal but does not establish linearity; clipping or charge-induced correlations biases a variance estimate. A large ensemble of suitable detector pixels supplies the measured standard deviation. In normal photodetector terminology is collected Electrons per ADU, consistent with detected photons here only under the stated unit-yield convention; see the instrument gain definition.
Past exam of the mathematics course of the University of Cambridge 2017 iii Paper 338 3 c iv Solution Created 2026-10-03 Updated 2026-10-06
If spatial illumination is stable between the two sums, it acts just like the sensitivity factor: the mean ratio remains one but each detector pixel has a different shot-noise variance. A whole-image standard deviation is disproportionately influenced by faint detector pixels, so substituting a global arithmetic mean signal generally underestimates detector conversion gain. If the illumination pattern differs between the sums, their noise-free ratio is not constant; its structure adds apparent variance and causes a further systematic error.
Use locally uniform signal bins or subregions, remove offsets, mask defective or saturated detector pixels, and propagate the local shot and read variances. In the stable-pattern case a useful alternative to pooling raw ratios is the normalized differenceAt high signal and negligible read noise, treating the denominator at its mean gives , independent of the illumination. Thus a variance fit or can use a spatially varying flat without the arithmetic/harmonic mismatch. Measured noisy denominators cause higher-order corrections, so independent or smoothed signal estimates can be preferable. Fit and subtract a genuine changing illumination pattern before noise analysis, using sufficient smoothing not to fit away the random noise. Arbitrary flat-field normalization without propagating its noise does not by itself recover the original gain.
Past exam of the mathematics course of the University of Cambridge 2018 iii Paper 219 1 iv Solution Created 2026-10-03 Updated 2026-10-05
Equal variances make every weight , so the inverse-variance weighted mean reduces to the arithmetic mean. Independence givesThus the variance scales as , whereas the uncertainty expressed as a standard deviation scales as .
Signal-to-noise ratio in photon counting 2026-10-05
For source counts and independent background counts with Poisson distributions, the ideal counting standard deviation is , so the signal-to-noise ratio is . Detector noise and uncertainty in the estimated background add further variance. A larger sky aperture raises , while better throughput raises ; both affect the faintness limit of a spectrograph.
Student t random-effect model 2026-10-06
A Student t random-effect model assigns Student's t-distributions to exchangeable study effects, allowing heavier tails than a normal distribution hierarchy. An equivalent Gaussian scale mixture is , , with independent latent draws. For the variance is , so is a scale rather than a standard deviation. Small latent precisions weaken shrinkage for atypical studies while retaining partial pooling for the rest.