Cheryl Smith Created 2026-10-14 Updated 2026-11-05
Cheryl Smith coauthored work on electronic balances and gravimetric applications, including pycnometer density measurement. Calibration and weighing at different temperatures require attention to the liquid's density and the calibrated vessel volume.
A precise mass reading is therefore one input to a density measurement. Temperature conventions and sample handling determine how that reading is converted into a material property.[ref]
The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass) by Randall M. Schoonover and others. Printed pages 313–316, pycnometer calibration and application
James Taylor (metrologist) Created 2026-10-14 Updated 2026-11-05
James Taylor coauthored research on electronic-balance measurements of solid and liquid mass density, mass, and vessel volume. The study explained how an electromagnetic restoring force returns a loaded balance to a sensed null position, then related the readings to buoyancy and measurement calibration. It also treated pycnometer density measurement, where temperature-dependent vessel capacity must be distinguished from the balance reading.[ref]
The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass) by Randall M. Schoonover and others. Printed p. 299 byline; pp. 302–305, balance operation; pp. 313–316, pycnometer calibration and application
Mei-Sywe Hwang Created 2026-10-14 Updated 2026-11-05
Mei-Sywe Hwang is identified as a statistician at the Center for Measurement Standards in Hsinchu, Taiwan, in a 1993 conference paper reprinted by NIST in 1994. The coauthored report examines electronic balances for gravimetric measurements, including solid and liquid density, pycnometer calibration and mass. Its examples connect a physical instrument's readings with corrections and uncertainty in an inferred quantity.[ref]
The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass) by Randall M. Schoonover and others. Printed p. 299, author role/affiliation, keywords and abstract; report cover, February 1994
The byline establishes her participation and historical affiliation; it does not identify an individual contribution to each experiment or establish later positions. The technical setting illustrates why measurement error and calibration are substantive parts of applied statistical work.
Pycnometer density measurement 2026-10-14
A pycnometer makes the distinction between mass and mass density experimentally tangible. NIST's 1994 report describes a glass vessel with filling capillaries, wire plugs and a covered overflow bowl in a controlled water bath. The operators soaked a pure-water filling to establish the bath temperature, dried the outside, then left it overnight in the balance enclosure to reach thermal equilibrium before weighing. Empty and full force-restoration balance readings, together with known water mass density, calibrated its capacity at the bath temperature. A tin-oxide coating suppressed stray electric charge; an electrometer detected none during use. The authors distinguish bath and weighing temperatures and correct for buoyancy and changes of displacement volume. Capacity and water-reference uncertainties carry into later liquid mass density determinations. Their pycnometer data were not yet analyzed, so this account provides no measured density or achieved precision.[ref]
The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass) by Randall M. Schoonover and others. The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass), NISTIR 5375, printed pp. 313–316, “Pycnometer Calibration”, Figure 5 and “Pycnometer Application”; p. 315 states that pycnometer data had not yet been analyzed
The ideal accounting behind this measurement calibration can be derived without numerical observations. Let denote corrected masses of the empty vessel, water-filled vessel and sample-filled vessel. At the same filling temperature, with known reference water mass density and reproducibly filled volume ,The empty-vessel subtraction removes vessel mass; the water filling sets volume. Doubling for the same uniform sample doubles the sample mass increment but preserves . Uncorrected balance indications, trapped bubbles, incomplete filling or unequal filling temperatures break the simple identification with corrected mass and a common . This explains why replication is a statement about comparable states rather than arbitrary instrument readings.
Randall M. Schoonover Created 2026-10-14 Updated 2026-11-05
Randall M. Schoonover investigated precision measurements of mass and mass density. A coauthored study used an electronic force balance to weigh a silicon crystal in air and water, applying buoyancy and measurement calibration corrections. The reported crystal density agreed with its accepted value within 2.4 parts per million.[ref]
The Electronic Balance and Some Gravimetric Applications (The Density of Solids and Liquids, Pycnometry and Mass) by Randall M. Schoonover and others. Printed pp. 299–300, abstract and hydrostatic-weighing principles
The method obtains mass density from the two buoyant-force readings and known fluid densities; it does not require an independent measurement of the crystal's volume.[ref]