Institutional faculty profile. About: Raman microspectroscopy, spectroscopic imaging, musculoskeletal tissue chemistry and response to loading. Representative Publications gives Michael D. Morris and William F. Finney in full. Research Areas lists analytical chemistry, bioanalytical chemistry, materials chemistry, optics and imaging. The identified portrait is the profile's Michael Morris image link.
Michael D. Morris, William F. Finney, Rupak M. Rajachar and David H. Kohn. Faraday Discussions 126 (2004), 159–168; DOI 10.1039/B304905A; first published 3 November 2003. The publisher's byline verifies the full names and University of Michigan affiliations. The Abstract describes hydrated murine femora loaded in tension in a mechanical tester fitted to a Raman microprobe stage; mineral phosphate-band shifts were recorded while loading remained in the elastic regime. Access verified through the publisher's indexed Abstract; direct full-text access was unavailable.
An openly readable abstract with the same byline and DOI is available at pubmed.ncbi.nlm.nih.gov/14992405/ . It describes a custom tester on the Raman microprobe stage, hydrated specimens, simultaneous loading measurements and mineral-band changes below yield. The abstract supplies these apparatus observations; no unavailable full-text details are inferred.
Three-page invited OFC paper, Anaheim, March 2001. The PDF title is Frequency response metrology for high-speed optical receivers; its exact byline is Paul D. Hale, Tracy S. Clement and Dylan F. Williams, National Institute of Standards and Technology. Page 1, Heterodyne measurements: two single-frequency lasers near 1319 nm, variable attenuators, beam splitter, polarizer and single-mode fibre produce mode-matched beating at a tunable difference frequency. Pages 1–2, equations 1–4 and Figure 1, separate the optical modulation model from electrical loss and impedance-mismatch corrections. No current instrument specifications are inferred from this historical apparatus.
A. Dubietis, G. Jonušauskas and A. Piskarskas, Optics Communications 88(4–6), 437–440 (1992). Published title and indexed bylines identify chirped and stretched pulse parametric amplification in BBO. Bibliographic record: cir.nii.ac.jp/crid/1360011145238718336 . Initial-only bylines are retained; no full-name expansion or experimental performance number is inferred.
Publisher Abstract: www.sciencedirect.com/science/article/abs/pii/0030401892900708 . It reports pulses compressed to 70 fs and approximately 0.9 GW output power for chirped and stretched pulse parametric amplification in BBO. The indexed publisher Abstract was verified; the direct page returned HTTP 403, so no unobserved full-text pump wavelength, crystal orientation or pulse-energy value is inferred. The exact byline remains A. Dubietis, G. Jonušauskas and A. Piskarskas.
Applied Optics42(6),1040–1047(2003), DOI10.1364/AO.42.001040. Primary byline Ian N.Ross, Marta Csatári and Steve Hutchins; CLF affiliation and i.n[email protected].uk match the1998/99 CLF directory. Abstract reports multipass saturated gain over6000, short-term output stability0.2% rms and long-term0.7% rms under the reported conditions.
Institutional announcement,7November2017, identifies Ric Allott and his photonics/industrial-laser work. It records his first CLF appointment in1995, later industrial work and return to STFC in2012. The1998/99 annual report editorial credits also give Ric Allott.
Central Laser Facility anniversary booklet,2017. Printedp.16, Optical Parametric Chirped Pulse Amplification: describes the Vulcan development programme and identifies John Collier and Ian Ross aligning an OPCPA test system in1999, photograph99RC1329. Original institutional copy: www.clf.stfc.ac.uk/Gallery/CLF%2040th%20Anniversary%20booklet%20for%20web%202.pdf .
Fellow profile identifies John Collier, specialist subject Laser Physics, elected2015, and Central Laser Facility affiliation. The CLF leadership listing clf.stfc.ac.uk/about-us/ gives the same name and institution.
Institutional staff biography: joined the CLF in1997 to develop laser technology for the Vulcan Petawatt upgrade; subsequently led Vulcan and the High Power Lasers Division. The current institutional leadership listing is clf.stfc.ac.uk/about-us/ , Meet the senior leadership team.
Department of Physics profile identifies Colin Danson and a research portfolio in ultra-high-power laser development and applications. The page describes his OxCHEDS work and provides the named profile photograph.
Applied Spectroscopy57(11),1317–1323, November2003. Publisher and author manuscript explicitly credit David W.McCamant, Philipp Kukura and Richard A.Mathies. Introduction and Figure1 distinguish the narrowband Raman pump from the broadband short probe and discuss spectral resolution. Materials and Methods, Instrumentation/Figure2, describes spectrally filtered pump light near793nm, a sapphire-generated continuum, spectrograph and dual-diode-array probe/reference detection; cyclohexane gain bands provide a non-biological physical-spectroscopy example. Data Collection, equation4, forms a dark-corrected, reference-normalized pump-on/pump-off gain ratio.
Data Collection specifies a 97 ms detector exposure containing 97 probe/reference pulse pairs, followed by 10 ms readout with detector-exposure shutter S2 closed. Raman-pump shutter S1 switches state during readout, producing alternating pump-on/off exposures. These simultaneous probe/reference measurements constrain exposure allocation in pairs; live exposure time excludes the closed-shutter readout. [ref]
Applied Spectroscopy59(4),393–400, April2005. The publisher's exact byline is P.Matousek, I.P.Clark, E.R.C.Draper, M.D.Morris, A.E.Goodship, N.Everall, M.Towrie, W.F.Finney and A.W.Parker. Abstract: collection regions laterally offset from the excitation spot change surface/subsurface spectral contributions; the physical feasibility sample was trans-stilbene powder beneath1mm of PMMA powder, with a19-fold unprocessed buried-layer contrast improvement. The abstract is the verified locator for this material experiment; no specific offset or wavelength is inferred from inaccessible full text.
Manufacturer technical description, opening paragraphs: identically shaped birefringent prisms with orthogonal crystal axes, divergent orthogonally polarized output beams, calcite/quartz implementations, and full output-angle convention. General specifications distinguish cemented calcite prisms from optically contacted quartz prisms. Technical construction and angle convention are cited; no catalog prices are relied on.
Manufacturer apparatus manual hosted by IIT Roorkee. Cover credits Raman Scientific Instruments, Roorkee. PDF pp2–5 describe the sodium source, slit, biprism, optical bench, micrometer eyepiece, two virtual slit images and fringe-width relation. PDF p2 gives the conjugate-lens separation method: the full virtual-source separation is the square root of the product of the two measured image separations. The manual denotes that full separation by2d; this differs from conventions using d for the full separation.
Central Laser Facility Annual Report1998/99, RAL-TR-1999-062, printedpp194–195, PDFpages185–186. Exact initial-only byline: J.Collier, C.Hernandez-Gomez, I.Ross, R.Allott, C.Danson, A.Hall, T.J.Spencer. Description/Figure2: frequency doubling, polarization separation, crossed-beam mixing and CCD recording. Results/Figure4: etalon-generated delayed replica near1.5×10^-3.
The 1998/99 report’s editorial credits and directory on printed p. 230 identify Colin Danson and Ian Ross, with addresses c.n[email protected].uk and i.n[email protected].uk. The same report credits Ric Allott as an editor. The article retains its initial-only published byline; its contact is j[email protected].uk.
Verified locator: Manufacturer technical sheet Ref.1211-e, printed copyright January2024. PDFp1 identifies Sequoia as a third-order cross-correlator for temporal contrast; p2 separately lists scanning range, scan resolution and optical temporal resolution.
Primary vendor documentation titled Plane wave and beam source - Simulation object. Frequency/Wavelength tab, Standard source: PULSELENGTH explicitly means full width at half maximum of the temporal power profile. No personal byline or publication date is asserted.
The standard-source PULSELENGTH setting is the temporal power FWHM. “Manual calculation of the source time signal” gives a sinusoidal carrier multiplied by a Gaussian field envelope and distinguishes the pulse length from the envelope parameter.
Manufacturer primary apparatus account: shared collimator/telescope optical path with beam splitter and reticle image at infinity; Checking straightness section, mirror support base b and height relation h=b tan(alpha). Numeric focal-plane example independently derived.
Manufacturer primary account: What is an Autocollimator; Principles of Operation; Digital vs Visual Autocollimators. Collimated outward beam, external reflector, focused return and detector/eyepiece. No marketing uniqueness or general accuracy claims reused.

Pinned article: Introduction to the OurBigBook Project

Welcome to the OurBigBook Project! Our goal is to create the perfect publishing platform for STEM subjects, and get university-level students to write the best free STEM tutorials ever.
Everyone is welcome to create an account and play with the site: ourbigbook.com/go/register. We belive that students themselves can write amazing tutorials, but teachers are welcome too. You can write about anything you want, it doesn't have to be STEM or even educational. Silly test content is very welcome and you won't be penalized in any way. Just keep it legal!
We have two killer features:
  1. topics: topics group articles by different users with the same title, e.g. here is the topic for the "Fundamental Theorem of Calculus" ourbigbook.com/go/topic/fundamental-theorem-of-calculus
    Articles of different users are sorted by upvote within each article page. This feature is a bit like:
    • a Wikipedia where each user can have their own version of each article
    • a Q&A website like Stack Overflow, where multiple people can give their views on a given topic, and the best ones are sorted by upvote. Except you don't need to wait for someone to ask first, and any topic goes, no matter how narrow or broad
    This feature makes it possible for readers to find better explanations of any topic created by other writers. And it allows writers to create an explanation in a place that readers might actually find it.
    Figure 1.
    Screenshot of the "Derivative" topic page
    . View it live at: ourbigbook.com/go/topic/derivative
  2. local editing: you can store all your personal knowledge base content locally in a plaintext markup format that can be edited locally and published either:
    This way you can be sure that even if OurBigBook.com were to go down one day (which we have no plans to do as it is quite cheap to host!), your content will still be perfectly readable as a static site.
    Figure 5. . You can also edit articles on the Web editor without installing anything locally.
    Video 3.
    Edit locally and publish demo
    . Source. This shows editing OurBigBook Markup and publishing it using the Visual Studio Code extension.
  3. https://raw.githubusercontent.com/ourbigbook/ourbigbook-media/master/feature/x/hilbert-space-arrow.png
  4. Infinitely deep tables of contents:
    Figure 6.
    Dynamic article tree with infinitely deep table of contents
    .
    Descendant pages can also show up as toplevel e.g.: ourbigbook.com/cirosantilli/chordate-subclade
All our software is open source and hosted at: github.com/ourbigbook/ourbigbook
Further documentation can be found at: docs.ourbigbook.com
Feel free to reach our to us for any help or suggestions: docs.ourbigbook.com/#contact