Model a spatially uniform cell membrane as a capacitor of membrane capacitance in parallel with membrane electrical resistance and a fixed leak reversal potential . Exclude active ion channels, seal leak current and pipette capacitance. For electric current injected into the biological cell, electric charge conservation yields
Starting at and applying constant gives the ordinary differential equation solution
The steady state rise is ; the time constant is . With , , and , the rise is and . At one time constant the rise is . The figure's uncompensated pipette voltage adds for . The membrane voltage is continuous at step onset in this model, while the pipette voltage immediately acquires that access drop.
Checking the units is instructive: electrical resistance times capacitance has units , and electric current times electrical resistance has units of voltage. Unlike the passive voltage clamp transient under patch-clamp series resistance, this ideal current clamp membrane time constant is set by , not . Strong current steps can recruit voltage-gated ion channels; the passive model then fails and cannot generate an action potential. Small pulses of both signs, stable access and repeated baseline measurements help test whether the passive approximation is appropriate.