The fractional excess of water-vapor pressure above equilibrium saturation over a flat pure-water surface at the same temperature: . Positive can drive droplet growth, but activation of a particular aerosol particle requires exceeding its critical supersaturation. Cooling, condensation and mixing jointly determine parcel supersaturation.
Cloud-droplet activation 2026-10-24
An aerosol particle becomes a freely growing cloud droplet after crossing its Köhler theory growth barrier under the parcel's atmospheric supersaturation history. Counting particles whose critical supersaturation is below a specified peak gives an equilibrium-threshold estimate; calculating that peak requires cooling, water vapor depletion and condensational-growth kinetics. Neither total aerosol number nor dry size alone determines activation.
Köhler curve 2026-10-25
The equilibrium saturation ratio over a chemical solution droplet as a function of wet radius for fixed solute content. In the dilute radius approximation , its maximum occurs at . The corresponding critical supersaturation is . Diameter and radius coefficients differ and must not be mixed.
Köhler theory Created 2026-10-20 Updated 2026-10-24
The equilibrium water-vapor saturation ratio above a solution droplet combines a curvature effect, which raises vapor pressure, with dissolved-solute reduction of water activity. Its maximum defines a critical supersaturation for activation. In a dilute hygroscopicity approximation using droplet diameter and dry diameter , , where . Then . These approximate forms assume the stated diameter convention and dilute solution; composition and surface tension must be consistent.[ref]
Activation as a cloud condensation nucleus depends primarily on dry particle size, soluble composition and hygroscopicity, together with wetting and surface-tension effects. In Köhler theory, droplet curvature raises the equilibrium vapor pressure, while dissolved solute lowers water activity. Each particle therefore has a critical supersaturation; larger or more hygroscopic particles generally activate at a lower value. A size distribution cannot be replaced by an undifferentiated total aerosol count.[ref]
Actual droplet number also depends on the supersaturation attained in the cloud updraught. Adding particles increases competition for condensing water vapor and can lower the peak supersaturation, leaving some particles unactivated. Updraught speed, entrainment and the aerosol size distribution therefore make the number of activated droplets a nonlinear function of the available nuclei. Suitable nuclei need sufficiently low activation thresholds, and additional aerosol does not guarantee one additional droplet per particle.
A rising parcel cools, lowering the saturation pressure. Once its water vapor supply exceeds that value, atmospheric supersaturation develops. Homogeneous nucleation of pure water is strongly inhibited at the small atmospheric supersaturations typical of clouds; existing aerosol particles provide cloud condensation nuclei. Their dry sizes and composition, together with the parcel's ascent rate, determine how many cloud droplets activate.
Köhler theory combines the Kelvin equation, which raises equilibrium vapor pressure over a curved surface, with Raoult's law, which lowers it for a chemical solution. In a dilute diameter convention, with dry diameter and wet diameter ,
Here is atmospheric supersaturation, is surface tension, and measures aerosol hygroscopicity, not the dry-adiabatic process exponent. The maximum of the Köhler curve is the critical supersaturation. Larger or more hygroscopic particles generally have lower thresholds. Cloud-droplet activation requires overcoming that maximum; total aerosol number is not the activated number.
Given an observed aerosol number size distribution for composition classes , first assign each class a hygroscopicity and compute its critical supersaturation. If the parcel reaches maximum atmospheric supersaturation , the equilibrium-threshold estimate is
For each fitted lognormal distribution, this is its upper-tail integral; it can be evaluated analytically with an error function or numerically from measured bins.
The value must be calculated, not guessed from the aerosol distribution alone. Prescribe parcel upward velocity , initial pressure, temperature and humidity, then integrate expansion cooling, latent heat release, conservation of total water, and diffusional cloud droplet growth. Schematically,
where , includes water vapor diffusion and thermal conduction, and is liquid mass fraction. Rising motion produces atmospheric supersaturation; growing particles consume it. Their competition selects the peak and which particles cross their activation barriers. Assume a well-mixed closed parcel, liquid water, soluble spherical particles, specified mixing state, and negligible collision-coalescence and fallout during activation. Slow kinetic growth, weakly soluble particles or entrainment require a more detailed treatment than the threshold integral.