A critically damped RLC response is the boundary between underdamped RLC response and overdamped RLC response. The free series RLC circuit has a repeated characteristic root , with general solution
For initial conditions , ,
In the plotted normalization, and . The electric charge returns without ringing; the polynomial factor matters, so a single exponential function does not give the whole response.
For fixed and these initial conditions, critical damping avoids ringing while giving a faster asymptotic return than any larger : the overdamped RLC response has a root closer to zero. This makes critical damping a useful tuning target for settling after switching. An MIT laboratory exercise makes the distinction observable by asking students to compare all three cases with and . Those values give and . [ref].