For jointly approximately normal estimates with estimated variances and covariance , a confidence interval for the ratio , where , can be obtained by inverting tests of . For each proposed ratio , the contrast has estimate and variance . Retain when its absolute standardized contrast is at most the chosen critical value . This gives the displayed quadratic inequality, with coefficients , , . When and the discriminant is positive, retain the interval between the roots. When , a confidence set can instead be two unbounded rays or the entire real line. Degenerate linear cases are interpreted directly from the inequality. A bounded interval must not be forced when the denominator is poorly separated from zero. Known covariance matrix and a joint normal distribution give exact normal critical values; estimated covariance usually gives approximate coverage, unless an appropriate exact common-scale pivot exists.