A fluorescent tracer is a marker detected through fluorescence whose distribution is used to infer transport, mixing or location. In a fluid experiment, a small amount of fluorescent dye can reveal where an injected portion of water travels. The marker's own motion and chemical interactions determine what it faithfully tracks.
A possible optical arrangement illuminates a sample at an excitation wavelength, rejects most excitation light with an emission filter, and records the remaining fluorescence with a detector. A fluorometer can turn this into a concentration measurement. For fixed optical conditions in a calibrated dilute regime, an illustrative model is
where is dye mass concentration. A fluorescence calibration curve establishes the usable range and background. Assuming linearity at every concentration would hide effects of absorption, quenching or detector response.
The same marker can measure a volumetric flow rate. For steady injection at rate and stock concentration into an upstream flow with background concentration , complete downstream mixing gives
For , , and , the inferred upstream flow is . The extra litre per second belongs to the injected stream.
The Bureau of Reclamation's manual describes this constant-injection method, requiring known injection rate, adequate downstream mixing and concentration measurement; fluorometers detect dye at levels too faint for visual comparison.[ref] Adsorption, photobleaching or incomplete mixing can invalidate an ideal conserved-tracer inference. Observing a bright pattern alone does not establish that the dye is a quantitatively faithful measure of every constituent's motion.