A spatially uniform pressure is a useful leading approximation when the sound speed makes the acoustic crossing time much shorter than the radiative cooling and thermal conduction times. The motions must remain at low Mach number, and gravity and other stresses must be negligible. Sound then redistributes pressure before appreciable thermal evolution occurs. Small pressure corrections can still drive the slow motion; imposing exactly zero pressure gradient in the full momentum equation at every order would be a stronger assumption.
The equation of state gives the specific internal energy of an ideal gas as . With , the continuity equation is . Differentiating therefore yields
Insert this into the internal energy equation, whose compressional term is , and use spatially uniform pressure, so . The result is
For temporally constant pressure put , so the mass density is . The continuity equation now gives . Multiplication of the last equation by , with , gives
This is the isobaric conductive cooling in mass coordinates transformation before changing coordinates.
There is a boundary assumption implicit in the proposed Lagrangian coordinate. For a mass integral from a fixed origin, integration of the continuity equation gives
Thus is material when the base mass flux vanishes, as appropriate for the stationary cold reservoir below. If the origin permits mass flux, replace by ; this corrected label has zero material derivative. In a material mass coordinate, and . In particular
The conduction coefficient therefore becomes , with the same as the cooling coefficient. With , the equation is
In the hot gas there is no volumetric radiative cooling. The initial temperature is uniform and the cold boundary introduces no finite mass length. The remaining nonlinear diffusion equation is invariant under , with the same temperature scale. Its natural similarity solution is therefore
The far-field condition also recovers the initial temperature at every fixed as . Substitution gives the ordinary differential equation
For , this reduces to . Integrating first for gives . The two boundary conditions fix , hence the error-function isobaric cooling front is
Here the error function has normalization , as printed in the original PDF; the converted TeX's is incorrect. The following original sketch shows the temperature profiles. The cooling layer broadens as , and at fixed positive mass label the temperature falls as time increases, while the remote hot gas remains at .
Figure 1.
Isobaric conductive cooling profiles at increasing scaled times
. Details.
For , the magnitude of the heat flux into the cold reservoir is
Although the thermal conductivity tends to zero there, the physical temperature gradient diverges: their product has this finite limit. The stationary reservoir has no incoming advective energy flux and radiates the conducted energy immediately. Since , the radiated power per unit area is
Thus the requested exponent is . The initial divergence is the usual idealization of an instantaneous temperature discontinuity in a diffusion equation.