Magnetic relaxation converts magnetic energy into material motion through the Lorentz force density, and dissipates the resulting kinetic energy through viscosity. In a perfect conductor, magnetic flux freezing preserves field-line connectivity throughout every smooth stage. A regular limiting state has zero velocity and is a magnetostatic equilibrium, but its magnetic field can contain current sheets. Conservation of one global magnetic helicity is weaker than preservation of the complete frozen field-line structure.
For a planar magnetic field , ideal induction advects the Cartesian magnetic flux function: . Incompressible flow also preserves the area inside each material contour. During relaxation, the arms of a magnetic separatrix can approach each other while their field-line connectivity remains fixed. A transition of width with a finite change of tangential field has electric current density of order and can approach a current sheet. This is a possible limiting mechanism, not a claim that every planar equilibrium is singular.
For constant mass density , kinematic viscosity , ideal induction, zero boundary velocity and tangent magnetic field, put . Multiplying the momentum equation by and integrating cancels pressure work and advective flux. The magnetic-energy derivative is minus the integral of Lorentz force density dotted with velocity, canceling the same work in the kinetic-energy equation. Integration by parts then gives the displayed identity. For incompressible flow with zero boundary velocity, .