Register forwarding supplies a later instruction with a computed value before that value has reached the register file. It removes some read-after-write hazards without changing the program's meaning. Consider these symbolic machine instructions, with the destination first:In the five-stage in-order pipeline, the addition produces its result at the end of EX. In the next cycle the subtraction is in EX, although the addition has not yet reached WB. A bypass from the addition's EX/MEM pipeline register to the subtraction's arithmetic logic unit input supplies the new
ADD r1, r2, r3
SUB r4, r1, r5r1; the old value read in ID must be overridden.The bypass control compares source and destination processor register identifiers and selects the youngest applicable older producer. It must also check that the producer actually writes that processor register. Forward the newest available result instead of waiting for its writeback. A load instruction is different: its value is normally available only at the end of MEM, so an immediately following dependent instruction still needs a pipeline stall in this five-stage arrangement.