Both neutron diffraction and X-ray diffraction use interference from atomic arrangements. Elastic scattering gives reciprocal-space peaks when the momentum transfer matches a reciprocal lattice vector. For a basis with sites , the structural amplitude is , and peak intensities constrain positions, occupancies and thermal displacement as well as lattice symmetry. Powder averaging loses some directional information that a suitable single-crystal measurement retains.
X-rays couple primarily to the electron distribution. Their atomic form factors generally favor heavier atoms and decrease with increasing scattering angle; the wavelength can also be tuned near an absorption edge for element-sensitive anomalous contrast. Neutrons scatter from nuclei with scattering lengths that vary irregularly with element and isotope. This can make light atoms visible beside heavy ones, and isotope substitution can change contrast without changing the nominal chemical element. In particular, replacing hydrogen with deuterium changes the balance of coherent and incoherent neutron scattering.
Neutron magnetic scattering also couples to electronic magnetic moments, allowing magnetic order to produce peaks distinct from the nuclear structure. X-ray magnetic scattering is possible too, especially under suitable resonant conditions; it is incorrect to say X-rays can never probe magnetism. Neutron experiments often require larger samples and dedicated sources, whereas X-ray scattering is available in laboratories as well as synchrotrons. Absorption, multiple scattering, texture and instrumental resolution affect both methods. Their complementarity comes from different contrast weights and magnetic sensitivity, rather than from two identical pictures of the same density.
In photoemission electron microscopy, illuminate a surface with ultraviolet light or X-rays and form an electron-optical image of the emitted electrons. An extraction field accelerates them away from the sample; an immersion objective and projection lenses magnify their spatial distribution onto an electron detector. Unlike a scanned probe, this is a full-field image. Surface preparation and vacuum matter because the emitted low-energy electrons are strongly affected by contamination and local electric fields.
Contrast can come from work-function differences, composition, occupied electronic states, illumination and topography. Near threshold, a small work-function change can produce a large emission-yield change. Therefore brightness is not simply geometrical height. An energy filter can select an emitted-electron energy interval; scanning the selection yields spatially resolved spectra. Sweeping the photon energy across an absorption edge can add element and chemical-state sensitivity. Appropriate polarization-dependent measurements can probe magnetic domains.[ref]
Resolution depends on electron-lens aberrations, the accepted angular and energy spread, extraction geometry, sample flatness, space charge, mechanical stability and detector sampling. Rejecting electrons improves some aberrations at a cost in signal. An unfiltered photoelectron image and a chemically selected image therefore answer different questions even when they use the same microscope.
In X-ray photoelectron spectroscopy, the electron binding energy relative to the chosen reference follows . A core-level chemical shift is a change in a core peak's binding energy between environments. Initial-state contributions include charge redistribution, bonding, the local electrostatic potential and chemical-potential changes. Final-state contributions include relaxation and screening of the newly created core hole. The measured shift contains both; it is not a direct meter of an integer oxidation state.
For a related chemical series, electron withdrawal often raises a core binding energy, but screening and referencing can change that trend. A surface core-level shift can separate surface atoms from bulk atoms because coordination and screening differ. Adsorption can introduce another component for chemically bound surface atoms. Spin-orbit doublets, multiplet or satellite features must be distinguished from separate chemical environments.
Reliable comparison needs a consistent Fermi-level or other justified energy reference, compensation or diagnosis of sample charging, adequate energy resolution and a stated line-shape/background model. Angle or photon-energy variation changes surface weighting through electron escape depth, helping distinguish surface and bulk assignments. A shifted, broader or overlapping peak alone does not uniquely identify a chemical species or its concentration.

Articles by others on the same topic (0)

There are currently no matching articles.