Minimize the residual sum of squares . Differentiating gives the normal equations . Full column rank makes positive definite and invertible, so the unique minimizer is
Since , it is unbiased. The independent common-variance errors give , hence
Independent Gaussian errors with common variance are a sufficient condition for this estimator also to be the maximum likelihood estimator: their log-likelihood differs from by terms independent of . Profiling an unknown common variance gives the same minimizer. Mean and variance assumptions alone do not specify a likelihood.
For the seven design points, and . In increasing time order the design matrix is
Its columns are mutually orthogonal: the odd sums vanish and . Their squared lengths are , respectively. Therefore
In particular . Testing for a quadratic contribution means testing against .
The cooling measurements are stated to have zero-mean errors and known common variance, but normality is not explicitly assumed for them. Under the independent-error linear regression model as stated, Chebyshev's inequality gives a valid conservative level- test: reject when
Its null rejection probability is at most because the estimator has mean zero and the calculated variance. If Gaussian errors are additionally assumed, the sharper exact test uses under the null and rejects for . With only seven observations, exact normal calibration cannot be deduced from the printed moment assumptions alone.

Articles by others on the same topic (0)