An Euler strut is a slender elastic column under axial compression. Let its bending stiffness about the weaker section axis be and its length be . With small lateral deflection and a dead compressive load , the quadratic total potential energy is
The first term is bending energy; the negative term is work released by the load as bending shortens the end-to-end distance. Stationarity gives . For pinned ends, at , and requires . The first instability is Euler's critical load,
Below this load, the straight state has positive quadratic energy against these perturbations. At the threshold, the lowest bending mode has zero quadratic restoring energy; above it the straight state is unstable. For a rectangular section, about the appropriate bending axis, so the smaller second moment of area controls the first buckling direction.
Endpoint constraints matter. Write : for pinned-pinned, for fixed-free and for fixed-fixed conditions. This elastic instability differs from compressive material failure. Imperfections cause bending before the ideal threshold, and a short column may yield before Euler buckling occurs.