The Shockley-Queisser calculation treats a single-junction solar cell with a single band gap, in steady state, with one collected electron-hole pair per absorbed above-gap photon, an ideal absorption edge, thermalized carriers and radiative recombination as the limiting recombination process. The source spectrum, cell temperature, angular acceptance and optical concentration must be specified. Below-gap photons are transmitted; energy above the gap is lost during carrier thermalization; the cell must emit photons by detailed balance, producing a recombination current and an entropy-related voltage loss. Delivering power at finite current also puts the operating voltage below the open-circuit voltage. Nonradiative recombination, resistance and imperfect collection worsen a real cell but are not required for the ideal limit.
Three ways to change those assumptions are tandem solar cells, which divide the spectrum among gaps and reduce both transmission and thermalization losses; hot-carrier solar cells, which aims to collect excess carrier energy before thermalization; and carrier multiplication or spectral conversion, which aims to use a high-energy photon for more than one excitation or combine otherwise unusable sub-gap photons. These concepts have additional practical losses and do not automatically outperform an optimized conventional device. The usual unconcentrated single-junction optimum is approximately one third under a terrestrial solar spectrum, rather than a universal efficiency independent of illumination.
For the geometrical estimate, take the stated horizontal equinox irradiance to set a constant direct-normal reference. The equinox solar-noon elevation is αe=90∘−51.75∘=38.25∘, so this reference is In=1/sinαe≃1.62kWm−2. A south-facing panel with tilt β=41.1∘ has noon incidence factor cos(51.75∘−δ−41.1∘), where δ=±23.44∘. Relative to the 1kWm−2 plane-of-array rating,These are the results of that idealized geometrical normalization, not credible seasonal production forecasts. Its inferred direct-normal irradiance already exceeds the approximately 1.36kWm−2 solar irradiance outside the atmosphere, so the supplied horizontal benchmark cannot describe a purely direct noon beam literally. Real direct and diffuse fractions, atmospheric attenuation at low winter elevation, cell temperature and inverter clipping are unspecified. An alternative assumption of 1kWm−2 direct-normal irradiance gives approximately 4.88 and 4.14 kW. A physically unique maximum cannot be inferred without an irradiance model.
PJune≃5sin38.25∘cos12.79∘=7.9kW,PDecember≃5sin38.25∘cos34.09∘=6.7kW.
The stated annual output corresponds to 4100/5=820 full-rated hours, an average power of 0.468 kW and a capacity factor of 9.4%. Night, cloud, seasonal day length and other losses explain the large difference from an instantaneous sunlit estimate.
For a national scale estimate, take UK area 2.44×1011m2, population 6.6×107, and annual mean solar input 100Wm−2. Covering five percent with twenty-percent-efficient modules givesThis is comparable with an order-100 kWh daily per-person primary-energy budget, and much larger than electricity use alone, of order 10-15 kWh per person per day. It is a gross area-and-flux estimate: access land, shading, seasonal storage, curtailment and conversion between primary energy and electrical end use all affect its interpretation.
NdayE∼1000(6.6×107)0.05(2.44×1011)(0.20)(100)(24)≃89kWhperson−1day−1.
Ancestors (11)
- 1
- S4
- 2018
- Past exam of the short options paper shared by Prelims and Parts A and B of the physics course of the University of Oxford
- Short options paper shared by Prelims and Parts A and B of the physics course of the University of Oxford
- Physics course of the University of Oxford
- Undergraduate course of the University of Oxford
- Course of the University of Oxford
- University of Oxford
- List of universities
- Home
Discussion (0)
New discussionThere are no discussions about this article yet.
Articles by others on the same topic (0)
There are currently no matching articles.