A periodic RC pulse-train baseline is the repeatable pre-pulse capacitor voltage reached after startup. It need not be zero even when the input low level is zero. With high duration , low duration , period , and , , the recurrence in residual baseline in RC pulse-width discrimination has contraction factor . Its fixed baseline and peak are
This is a deterministic periodic state, not a random noise floor. The startup error is reduced by a specified fraction after cycles, rounded upward.
The mean supplies an independent check. Integrating over a full period makes the derivative term vanish, so . The mean depends on duty cycle while the baseline and ripple depend on period relative to the time constant. For at fixed , expansion gives
Thus a rapid train approaches a level near its duty-cycle average, rather than isolated relaxed pulses.
For an original fast-train example, choose , , and . The exact baseline is about , the peak , and the mean exactly . The startup deviation contracts by each cycle; reducing it below one percent of its initial value takes 24 cycles, or .
A pulse-generator/oscilloscope test should therefore distinguish the first pulses from the repeatable train, and record minima, maxima and mean rather than only input width. The natural-response measurement in the primary RC laboratory checks the time constant used here.[ref] Threshold placement relative to the repeatable minimum and maximum determines acceptance and missing comparator reset in an RC pulse train.
A capacitor need not finish discharging before the next pulse arrives. This residual baseline in RC pulse-width discrimination changes the next pulse's RC threshold-crossing time even if its applied height and duration are unchanged. The relaxed-state acceptance formula assumes an initial output of zero; a repeated pulse train can violate that assumption systematically.
Take a first-order RC circuit with time constant , input high level , zero input low level and initial capacitor output . During a pulse of duration ,
For , solving for the rising threshold gives
A finite interval above threshold requires . At equality the output only touches the threshold at its peak. A positive residual makes the crossing earlier than the zero-baseline crossing. If the output already exceeds the threshold at the start, this rising-crossing formula no longer describes a new edge.
The input of a repeated pulse train is a periodic function with high duration , low duration and period . Put and . The next baseline is the previous peak multiplied by . Writing for the baseline before pulse gives the linear recurrence relation
Because , the deviation from its fixed point is a decaying geometric sequence:
This periodic RC pulse-train baseline is a repeatable state of the circuit, rather than random readout noise. In the periodic regime, separate rising and falling comparator transitions require . If , there is no finite high interval. If , there is no finite low interval: missing comparator reset in an RC pulse train can turn repeated input pulses into one sustained output state.
For an original calculation, choose , , , and . An isolated relaxed pulse peaks at only and is rejected. The repeatable train instead has
Its rising threshold occurs after each pulse starts. The falling crossing is , giving an above-threshold duration of . Starting from zero baseline, the first three pulses are rejected, but the fourth peaks at and crosses. A change in pulse acceptance need not mean that the source pulse itself changed.
Figure 1.
Residual capacitor charge makes a repeated short pulse cross a threshold that rejects the isolated pulse
. Original first-order model, with a 1 µs time constant, 0.4 µs high interval, 0.6 µs low interval and a half-height threshold. The first train starts relaxed; the second panel shows the repeatable baseline and peak. No measured waveforms are used. Details.
A useful design bound controls timing error rather than merely calling the circuit discharged. Put and suppose . Relative to the relaxed crossing,
Since a nonnegative pulse train in this model has , a low interval guarantees that baseline bound. Combining the inequalities yields a sufficient quiet interval required for an RC baseline timing budget :
For a 1% baseline allowance, limits the crossing advance to , or when . The bound is conservative because it uses the largest possible peak.
A bench test holds pulse height, duration and threshold fixed while sweeping repetition period with a pulse generator. Record the actual input and capacitor output on an oscilloscope, including the baseline immediately before each pulse. Probe capacitance and effective source electrical resistance belong in . MIT's laboratory uses repetitive square-wave excitation to measure RC decay, providing a direct way to check the underlying time constant.[ref] The calculations above assume ideal input edges and zero input low level; comparator hysteresis and switching dynamics require their own model.