A periodic RC pulse-train baseline is the repeatable pre-pulse capacitor voltage reached after startup. It need not be zero even when the input low level is zero. With high duration , low duration , period , and , , the recurrence in residual baseline in RC pulse-width discrimination has contraction factor . Its fixed baseline and peak areThis is a deterministic periodic state, not a random noise floor. The startup error is reduced by a specified fraction after cycles, rounded upward.
The mean supplies an independent check. Integrating over a full period makes the derivative term vanish, so . The mean depends on duty cycle while the baseline and ripple depend on period relative to the time constant. For at fixed , expansion givesThus a rapid train approaches a level near its duty-cycle average, rather than isolated relaxed pulses.
For an original fast-train example, choose , , and . The exact baseline is about , the peak , and the mean exactly . The startup deviation contracts by each cycle; reducing it below one percent of its initial value takes 24 cycles, or .
A pulse-generator/oscilloscope test should therefore distinguish the first pulses from the repeatable train, and record minima, maxima and mean rather than only input width. The natural-response measurement in the primary RC laboratory checks the time constant used here.[ref]
Laboratory 11: Sinusoidal Steady State Response of RC and RL Circuits by MIT OpenCourseWare. Printed pp. 1–2
Threshold placement relative to the repeatable minimum and maximum determines acceptance and missing comparator reset in an RC pulse train. Articles by others on the same topic