A pulse train is a sequence of pulses. An ideal periodic pulse train repeats the same waveform at a fixed period , with pulse repetition frequency . A finite burst, varying pulse heights or pulse timing jitter can break exact periodicity without removing the useful description as a pulse train. The repetition interval describes spacing; it is distinct from one pulse's duration.
If is one localized waveform, an ideal infinite pulse train isEquivalently, it is the convolution of with a Dirac comb. Its Fourier series coefficients are samples of the single pulse's Fourier transform:Thus the repetition period sets harmonic spacing , while the pulse shape sets the coefficient envelope. This statement concerns the repeated waveform itself; an optical electric field additionally has carrier phase information that a measured optical-power trace does not contain.
For optical power pulses with negligible continuous background, the average power of a laser pulse train obeys when every complete pulse has laser pulse energy . For a nonoverlapping rectangular pulse of duration , and the duty cycle is , so . For other shapes, a width such as the full width at half maximum needs a pulse energy shape factor before it determines peak power.[ref]
Average and Peak Power - A Tutorial by Newport. Photonics Technical Note1, one-page rectangular-pulse diagram and average-power/duty-cycle equations
An original rectangular example has , and . The pulse repetition frequency is , the duty cycle is , the peak power is and the average power is . A slow power meter can report that average while failing to resolve either the width or individual pulse-to-pulse energy fluctuation.
A fast photodetector and oscilloscope instead display successive electrical responses. Their bandwidth and impulse response limit the optical timing information available. Counting the spacing tests the pulse repetition frequency; integrating calibrated individual responses tests laser pulse energy. Pulse energy measurement with a photodiode explains the charge-integration step. Separating those measurements avoids inferring the pulse width from an average-power reading alone.
Articles by others on the same topic