Bessel function Created 2026-09-24 Updated 2026-11-05
Bessel functions are standard solutions of the ordinary differential equationThe parameter is the order. A first-kind solution iswhere is the gamma function and a branch of a multivalued function is chosen for a noninteger power. For nonnegative integer , is entire; a second-kind solution is singular at zero.[ref]
These functions arise when separation of variables is applied to the Helmholtz equation in cylindrical coordinates. A circular membrane requires a radial solution regular at the centre, selecting ; its boundary condition then selects zeros of . For example, is the radial profile for the rotationally symmetric family.
Volumetric analysis determines an amount of substance from the measured volume of a reagent of known strength that reacts with it in a known proportion. A measured aliquot is placed in a suitable vessel, the standard solution is delivered from a burette, and the volume required to reach the chosen titration endpoint is read. A pipette measures the aliquot; a volumetric flask prepares or dilutes the standard solution.
For a reaction , if the concentration of the titrant is and the corrected volume delivered is , thenWith volume in litres and concentration in moles per litre, the answer is an amount in moles. The corresponding mass is , using the appropriate molar mass. For an unknown solution of aliquot volume ,These are modern symbols for the same proportional reasoning that a nineteenth-century analyst could express with equivalent weights and a specified standard solution.
[ref]
IUPAC Compendium of Chemical Terminology (Gold Book) by International Union of Pure and Applied Chemistry. titration; volumetric titration, terms T06387 and 09055
A suitable reaction is sufficiently rapid, complete and selective, with a recognisable endpoint. In an acid-base titration, an indicator can change colour near neutralization; other reactions use precipitation, redox or a colour intrinsic to a reagent. The observed titration endpoint must represent the required equivalence point closely enough. The reagent's nominal preparation alone is insufficient if its concentration changes in storage; standardisation of a solution, a reagent blank where needed, and correct reading of the meniscus control systematic error. A titration measures the intended analyte only insofar as interfering substances have been excluded or accounted for.
Stock solution 2026-11-05
A stock solution is a chemical solution kept as a source from which other chemical solutions are prepared, commonly by dilution. Its known concentration makes repeated preparations traceable to one starting composition. A stock used for measurement calibration must also satisfy the requirements of a standard solution; the word stock alone does not establish that status. The original EPA Method200.8 defines calibration standards as dilutions of stock standards used to relate instrument response to analyte concentration.[ref]
Method 200.8 revision 5.4 by United States Environmental Protection Agency. §3.2, Calibration Standard; §7.4, calibration standards
Suppose an invented stock solution has molar concentration . To obtain final volume at , conservation of dissolved amount of substance givesTransfer that aliquot and add solvent to the final 50.0-millilitre mark of a volumetric flask, then mix. Adding 50.0 millilitres of solvent would specify a different operation: the equation requires final total volume.
The same inventory reasoning underlies serial dilution. A tenfold dilution followed by a fivefold dilution gives the same final concentration reduction of50, provided each transferred portion is representative and the counted solute is conserved. Reactions, losses or incomplete mixing would change those premises.
Volumetric analysis 2026-10-31
Quantitative analytical chemistry using the measured volume of a standard solution and a known reaction proportion.