Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld by Walther Gerlach and Otto Stern Created 2026-10-18 Updated 2026-11-05
By Walther Gerlach and Otto Stern. Zeitschrift für Physik 9, 349–352 (1922), received 1 March. English translation by Martin Bauer, arXiv:2301.11343v1, 26 January 2023.
Otto Stern Created 2026-10-18 Updated 2026-11-05
Otto Stern developed molecular-beam methods that infer microscopic properties from controlled particle trajectories. With Walther Gerlach, he sent a neutral silver beam through a magnetic field gradient, producing discrete deposited components. The beam's translational motion carries information about its internal magnetic moment projection to a macroscopic detector. Changing the magnetic field geometry or the beam preparation changes that mapping, making the apparatus part of the interpretation of the Stern-Gerlach experiment.[ref]
Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld by Walther Gerlach and Otto Stern. Original beam-splitting experiment
[ref]The Method of Molecular Rays by Otto Stern. Nobel lecture: trajectory methods and magnetic-moment measurements
A physicist.[ref]
Otto Stern - Facts by Nobel Prize Outreach. Biographical identity and professional specialization
The Stern-Gerlach experiment with Walther Gerlach tested the deflection of a neutral silver atomic beam in a nonuniform magnetic field.
Portrait of Otto Stern
. From Nobelprize.org; photographer not identified on the Commons file page. Public domain in Sweden under the conditions stated on the Commons file page. Source usage terms, via Wikimedia Commons. Source. Stern-Gerlach apparatus in 1922 Created 2026-10-18 Updated 2026-10-25
In 1922, Otto Stern and Walther Gerlach used an electrically heated oven to emit neutral silver chemical atoms. Two platinum apertures, a pinhole and a slit – wide, supplied collimation. The beam passed along a knife-edge pole in a nonuniform magnetic field. At its end, a glass plate collected the condensed silver. Continuous pumping maintained vacuum; the thin deposit required development even after eight hours.[ref]
Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld by Walther Gerlach and Otto Stern. Experimental setup, paragraphs 1–5; original 1922 paper in Martin Bauer's translation, PDF pp. 2–3
The field-off image established the undeflected slit width. A comparison put field-on and field-off deposits on the same plate. Microscopy revealed two deflected bands, no detectable central component, and broadening attributed to the velocity distribution. Alignment and distance from the knife-edge affected the pattern; precise magnetic field gradient measurements were still pending.[ref]
Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld by Walther Gerlach and Otto Stern. Results, Figs. 2–5 and observations b–e; closing paragraph, PDF pp. 3–5
The apertures act as a collimator: they constrain the initial transverse positions and velocities, so a magnetic displacement can be distinguished from an initially broad beam. Vacuum reduces collisions that would destroy this preparation. Deposition integrates arrivals over the exposure; a darkened band is not a time-resolved record of individual chemical atoms. The field-off comparison tests whether the magnet changes the spatial distribution, while alignment checks address a geometric source of apparent asymmetry. Finite sensitivity qualifies the absence of a central deposit: it is an experimental upper limit, not a proof that exactly zero atoms landed there.
Display of the Stern-Gerlach apparatus at the University of Hamburg
. Photograph by Lesendes Okapi, 29 January 2019, CC BY-SA 4.0, via Wikimedia Commons. The display in the Institute of Physical Chemistry includes an apparatus arrangement and a plaque honouring Otto Stern. This photograph documents the later exhibition. Source. Walther Gerlach Created 2026-10-18 Updated 2026-11-05
Walther Gerlach and Otto Stern sent a neutral silver atomic beam through a nonuniform magnetic field. Its deposited trace separated into discrete components instead of the continuous range expected from an elementary classical orientation model. The magnetic field gradient converts different magnetic moment projections into distinct trajectories; a uniform magnetic field lacks the required separating force. The Stern-Gerlach experiment thus makes the field geometry essential to the observation, while its modern spin interpretation differs from the original expectations.[ref]
Der experimentelle Nachweis der Richtungsquantelung im Magnetfeld by Walther Gerlach and Otto Stern. Original experiment and beam-deposition result
A physicist.[ref]
https://www.physik.lmu.de/de/quantenjahr-2025/geschichte-der-quantenphysik/. Biographical identity and professional specialization
Portrait of Walther Gerlach
. The Stern-Gerlach experiment, with Otto Stern, sent a neutral silver atomic beam through a nonuniform magnetic field and recorded its deposition pattern.