For a nonnegative integer , let count overlapping occurrences of in its binary expansion. The Rudin-Shapiro sign sequence is . Appending a binary digit gives and .
A longest common subsequence of two finite sequences has maximum length among sequences that occur in both with their original order. Characters can be skipped; this differs from requiring a contiguous substring. For and , is a common subsequence of length four.
A shortest common supersequence of two finite sequences is a shortest sequence containing each as a subsequence. Order is retained, but occurrences need not be contiguous. For and , is such a sequence; is another.
For lengths , its length is , where is the longest common subsequence length. Align a common subsequence of maximal length and merge the unmatched portions to prove the upper bound. Conversely, an alignment inside any common supersequence identifies at least shared positions when its length is , proving the lower bound. This formula is for two inputs; several inputs require a different analysis.
A one-dimensional Kronecker sequence is the sequence of fractional parts for . If is rational, it is periodic. If is irrational, its terms are equidistributed sequence: the proportion lying in tends to .
For any nonzero integer , the average tends to zero by the finite geometric series, since . The Weyl criterion converts these cancellations into uniform distribution. In several dimensions, use coordinatewise; uniform distribution requires that be linearly independent over the rational numbers.
A sequence is eventually periodic if there are integers and such that for all . It consists of a finite initial segment followed by a repeating period. Checking finitely many repeated values can suggest eventual periodicity, but a proof requires a reason the repetition continues, such as recurrence of a complete state in a deterministic finite-state process.
A longest nondecreasing subsequence selects indices with and makes as large as possible. Selected terms need not be contiguous. In , the terms form one of length three.
An algorithm stores the smallest possible final value for each attainable length. For each new value , binary-search for the first stored tail strictly greater than and replace it, or append if none exists. Equal values therefore extend the sequence. For the strictly increasing variant, search for the first tail greater than or equal to instead; changing this comparison changes the problem.
A member of a seed-plant lineage whose ovules are not enclosed in angiosperm carpels. Conifers contribute extensively to forest carbon pools, but the lineage includes different growth forms and reproductive arrangements.
The number of children of a node in a search tree, or an upper bound on that number over the tree. With branching factor at most and depth at most , a complete traversal visits at most nodes.
Energy-dependent Schwarzschild material capture threshold by
Codex 0 Created 2026-10-20 Updated 2026-10-31
For an incoming timelike Schwarzschild geodesic with asymptotic Lorentz factor , the critical unstable circular orbit obeysAt , and . For , the critical radius lies between and and . The marginally bound angular-momentum bound remains sufficient at larger energies but is no longer the exact threshold. Origin at infinity and an inward initial branch are essential; an orbit already inside a barrier is a different initial value problem.
For regular low-energy elastic scattering by a finite-range central potential, higher partial waves are suppressed by their centrifugal barriers. Matching the regular interior radial solution to small-argument exterior spherical Bessel functions gives the displayed scaling of scattering phase shift, in the generic absence of a threshold singularity. Since the channel amplitude is proportional to , it scales as . The term is isotropic and normally leads. A tuned vanishing leading amplitude or a threshold resonance requires examining the next terms rather than applying the generic statement blindly.
The zero-energy parameter of the angular-momentum-zero partial wave. For a short-range interaction in three dimensions, its leading elastic scattering amplitude is when effective-range corrections are negligible. For identical dilute bosons this parameter fixes the leading contact coupling .
This zero-range boundary condition replaces a short-range interaction by its S-wave scattering length. If , it requires . An outgoing spherical wave also has a constant term; retaining that term gives the unitary scattering-length amplitude . The model neglects effective-range corrections and is applied outside the microscopic range, not literally inside a finite potential.
Scanning transmission electron microscopy forms an image by scanning a focused electron probe across a thin specimen and recording transmitted or scattered electrons at each probe position. The detector's angular range determines which interaction contributes to the recorded brightness.
A detector including the direct beam gives a different image contrast mechanism from an annular detector collecting scattered electrons. High-angle annular dark-field imaging can emphasize composition and mass-thickness differences, but specimen thickness and channeling still affect interpretation. The probe size limits spatial detail, whereas the displayed-to-scanned length ratio sets magnification; increasing the latter cannot sharpen the probe.
An Everhart–Thornley detector converts emitted electrons into an amplified optical signal in a scanning electron microscope. A positively biased collector attracts low-energy secondary electrons toward a scintillator; their impact produces light carried through a light guide to a photomultiplier.
The measured brightness depends on how many emitted electrons reach the collector, not just on how many leave the surface. Changing specimen tilt or collector bias can therefore change an image without changing composition. Comparing such settings helps identify collection-geometry effects in secondary-electron topographic contrast. [ref]
https://www.jeol.com/words/semterms/20121024.070858.php. JEOL manufacturer glossary, SED: scintillator, light guide and photomultiplier arrangement
A scanning electron microscope permitting a controlled gaseous specimen environment while maintaining the electron column at lower pressure by differential pumping. Ionization of the gas supplies positive ions that can neutralize negative specimen charging, and a suitable gaseous detector collects electron signals. This enables examination of some nonconducting uncoated specimens, with gas scattering and detector response included in interpretation.
Image contrast from changes in secondary-electron escape and collection as surface slope, edges and detector-facing geometry vary. Secondary electrons originate near the surface, but brightness also depends on material, charging and the beam conditions.
There are unlisted articles, also show them or only show them.