Bicinchoninic acid assay Created 2026-10-14 Updated 2026-10-20
An assay that estimates protein concentration from a colour-producing chemical reaction, measured by absorbance and compared with known protein reference samples. Bovine serum albumin is commonly used as the reference protein. The readout estimates protein content rather than identifying each protein in a mixture.
Bradford assay Created 2026-10-20 Updated 2026-11-05
A dye-binding estimate of protein concentration using a calibration series and absorbance near . Protein-dependent dye response, buffer interference and blank treatment limit how directly a bovine serum albumin standard estimates another protein.
The manufacturer-issued Protein Preparation Handbook reports a paired dialysis comparison: of bovine serum albumin, in sodium chloride, was held behind a MWCO membrane against of water in a conical tube, shaken at room temperature. The bath was replaced after two hours. A conventional stirred-beaker treatment against of water supplied the comparison control. Residual salt was followed by sample electrical conductivity; results averaged two samples. This readout tests small-ion removal, not protein retention.[ref]
Protein Preparation Handbook, Thermo Fisher Scientific. Protein Preparation Handbook, printed p. 11, Figure 9A and caption: sample preparation, 10K membrane, baths, conductivity and conventional-dialysis reference
Its separate retention experiment used individual proteins at in saline or carbonate-bicarbonate buffer solution, pH , with membranes rated , , , and . After seventeen hours at , retained protein was estimated by a bicinchoninic acid assay. The size series and membrane series compare retention; they do not isolate shape independently of mass. The figure caption supplies neither a no-membrane recovery control nor a complete uncertainty analysis. These are manufacturer comparisons, not proof of universal recovery or unchanged enzyme function.[ref]
Protein Preparation Handbook, Thermo Fisher Scientific. Protein Preparation Handbook, printed p. 11, Figure 8 and caption: membrane series, preparation, duration, temperature and protein assay; the separately plotted vitamin B12 uses a different optical readout
The two experiments answer complementary questions: did the small solute leave, and did the desired macromolecule remain? In a new experiment, a bath blank and a starting salt standard would help interpret electrical conductivity, while a matched undialyzed protein aliquot and recovered volume would help distinguish handling loss from dilution. Those are proposed additional controls, not controls claimed for the published figures. Other ions also contribute to electrical conductivity, so the readout cannot generally identify sodium chloride alone in an unfamiliar buffer solution.
The dilution in the Bradford assay is . Read the fitted line rather than assuming it passes through the origin: the two absorbances correspond approximately to and in the assay mixture. ThereforeMultiplying by the eluate volume gives about of TEM-1 and of TEM-52. Only TEM-52 meets the requirement.
Assuming the same recovery per culture volume, the required volumes areUse approximately or more for TEM-1; the existing is sufficient for TEM-52. Rounding the former up to is sensible given graphical precision. Reading the lower standard as – gives a corresponding requirement of roughly –, not an exact integer volume. These estimates assume comparable dye response to bovine serum albumin, suitable buffer blanks and that recovered protein is the purified target; contaminants would inflate the inferred target yield.