Electronic gain expresses how an electronic circuit scales a specified input signal quantity into an output quantity. For a linearized voltage amplifier around its operating point, the voltage gain is . At a sinusoidal frequency it can be a complex phasor ratio, specifying both amplitude ratio and phase shift. Power gain instead compares the average power delivered to the load with the average signal power entering the amplifier:
State the input/output quantities, frequency, load and operating conditions when specifying gain. A transimpedance amplifier relates output electric potential difference to input current and has a dimensional transfer ratio in ohms.
For an original circuit example, use an inverting operational amplifier with input resistor , feedback resistor and load . In its ideal negative-feedback linear regime,
An input of root mean square therefore gives root mean square at the output, with a phase inversion. The manufacturer's primary explanation derives this resistance-ratio gain using the input and feedback currents.[ref] Suitable supplies, output-current capability and amplifier output range are assumptions of this worked model, not specifications of a particular device.
Here the input resistance is in the ideal model. For resistive ports and root-mean-square signal amplitudes,
The example input power is and load power , giving . The additional output energy comes from the amplifier's supply, controlled by the input signal. The impedance condition for converting voltage gain to power gain is essential: voltage magnitude alone does not specify load power.
Voltage gain is conventionally expressed as decibels, while power gain uses . This example has voltage gain and power gain ; the two expressions agree when the resistive input and load impedances are equal. A negative voltage gain indicates phase inversion; its magnitude enters the logarithm.
A direct test drives a small sine wave into the input and measures the actual terminal signals with an oscilloscope. Sweeping frequency reveals the frequency response; increasing amplitude reveals amplifier clipping or other departure from the assumed linear gain. Keep the load and measurement impedances specified. Gain can amplify input noise along with signal, so the signal-to-noise ratio requires its own measurement.
A voltage gain determines a power gain only when the electrical conditions at both ports are included. The familiar equality between and requires a particular impedance relation; it is not a conversion between arbitrary voltage and power ratios.
Use phasors whose moduli are root mean square amplitudes, at one sinusoidal frequency. At a load with electrical impedance and electrical admittance , the current is . Its complex electrical power is , with the complex conjugate arising from the relative phase of the two sinusoids. Averaging over a cycle gives the active power
To see the averaging step, write and similarly for . The product's cycle average is , the real part of . Peak-amplitude phasors instead require an extra factor .
Let describe the actual input impedance and the actual load impedance. Take and with nonzero terminal signals, and define currents into the amplifier at the input and into the load at the output. With the measured loaded voltage gain ,
Thus requires equality of the relevant electrical conductances, not merely equality of impedance moduli. For example, input and load both have modulus , but their electrical admittances have real parts and . The multiplier is , so .
For real resistive ports this becomes
Take an original example with measured , and . The voltage gain is , while the power gain is , or . An active buffer can reduce the signal's electric potential difference while delivering more signal power than it accepts at its input; the supply provides the additional energy.
The amplifier's output impedance is distinct from the connected load impedance. To show why that distinction matters, model its output by a Thévenin equivalent with open-circuit voltage and series resistance . The voltage divider gives
With and , the load produces the preceding example. Differentiating gives , so delivered power is largest at , as in the maximum power transfer theorem. Here its power gain is . Increasing much further makes approach but reduces delivered power. That high-load-impedance regime is impedance bridging, useful for sensing the source's voltage with little loading.
Figure 1.
Voltage transfer and delivered power respond differently to the same load resistance
. Original Thévenin amplifier model with open-circuit voltage gain 0.6, output resistance 10 ohms and input resistance 10 kilohms. The measured voltage gain increases toward 0.6 as the load grows; power gain peaks at a 10-ohm load. The marked 50-ohm point has voltage gain 0.5 and power gain 50. Details.
A bench demonstration uses a function generator, a known termination and an oscilloscope. The Keysight guide explains that an expected-load setting changes how amplitude is displayed for generators with a fixed series output impedance; a high-impedance load can receive twice the voltage expected for a matched termination.[ref] As an independent low-frequency resistive calculation, an open-circuit source of root mean square with series resistance delivers and to . Into it delivers about but only . The larger terminal reading accompanies much less delivered power. Specify the actual load, frequency and amplitude convention when comparing gain measurements.

Articles by others on the same topic (0)

There are currently no matching articles.