An energy-normalized pulse profile separates an optical pulse's temporal shape from its total laser pulse energy. For nonnegative radiant power and finite , define . Then has units inverse time and integrates to one. The radiant energy in a time interval is times the integral of over that interval.[ref]
International Lighting Vocabulary by CIE. Entry17-21-041, note1, radiant energy as integrated radiant flux
For an original two-lobe example, let during and during , with zero values elsewhere. The two integrals are and . Choosing gives powers and , and energies and . Multiplying by two doubles both powers without changing .
The temporal energy centroid of an optical pulse is when this moment exists. Here it is , in the gap between lobes. An energy centroid need not be a location of maximum power.
Mathematically, is a probability density function, but its weighting here is energy over time. It is not automatically a measured photon-arrival distribution, particularly when photon energies vary. A zero-energy trace cannot be normalized this way, and a noisy baseline-corrected trace with negative excursions is not automatically a nonnegative density. The Gaussian pulse energy and peak power article gives one normalized shape family.
The temporal energy centroid of an optical pulse is its energy-weighted mean time. For nonnegative radiant power with finite positive energy and finite absolute first moment,The normalization uses radiant energy as integrated radiant flux.[ref]
International Lighting Vocabulary by CIE. entry 17-21-041, note 1
The centroid is a moment of the energy-normalized pulse profile; it need not coincide with the largest power value, a threshold crossing or the middle of the FWHM interval.For an original two-component example, let ninety percent of the energy belong to a symmetric narrow component centred at zero and ten percent to a symmetric component centred at . Linearity of the integral gives . Weak delayed energy can move the centroid even when the dominant peak remains near zero. Multiplying the whole power trace by a positive constant leaves unchanged; translating it by shifts its centroid by .
A detector response can shift the measured centroid too. Suppose a normalized impulse response and normalized optical profile have finite absolute first moments. For their convolution , direct integration with givesThus a causal exponential detector response of time constant shifts the recorded centroid by in this model. NIST's pulsed-radiometer characterization explicitly measures detector impulse responses and uses convolution to assess reproduced waveforms.[ref]
Calibration Service for Low-level Pulsed-Laser Radiometers at 1.06 µm: Pulse Energy and Peak Power by Rodney W. Leonhardt. §§6.1–6.2, printed pp. 13–15
The centroid identity is the independent moment calculation above.Baseline drift can cause a separate shift. Suppose a true pulse has and , but a positive residual baseline of remains across the analysis window from to . Its added energy is , centred at . The resulting centroid isA waveform measurement should therefore record the time window, baseline estimate and detector timing response with its reported centroid. A negative background-subtracted trace also needs care: it is not automatically a nonnegative energy distribution.
Articles by others on the same topic
There are currently no matching articles.